WP01_1_2010_de_en_fr_it_V10.doc 39 / 96<br />

From the “Standby” mode, press “Menu OK” three times: Query of different operation modes:<br />

Display<br />

Parameters,<br />

Output level,<br />

Temperature<br />

value<br />

or<br />

Read current<br />

time<br />

INFO<br />

Step Description Display menu<br />

Press the “Menu OK” three times -<br />

Under the menu item “INFO”, different parameters such as<br />

number of rotations (rpm) of extractor fan, rpm of transverse<br />

blower, software version, operation hours and the next time of<br />

servicing can be read.<br />

Preferred parameters can be selected using ↑↓; with “Menu OK”<br />

the corresponding value is shown.<br />

Press “Menu OK” four times -<br />

Return to standard display using “Menu OK”, ↑↓ up to INFO<br />

appears, “Menu OK” up to standard display.<br />

SAFETY TEMPERATURE DELIMITER (STB), MAIN FUSE<br />

Step Description Display menu<br />

The safety temperature delimiter (STB) is a stipulated safety<br />

device, which turns off the equipment upon intense overheating<br />

and can be manually unlocked (with a pointed object).<br />

If the STB does not allow permanent pressing, the temperature is<br />

still too high, wait for sufficient cooling down.<br />

The release knob and the electric main fuse are on the rear of the<br />

stove.<br />

POWER CUT<br />

Step Description Display menu<br />

After a brief interruption in the power supply, the stove<br />

automatically resumes operation in the previously active state.<br />

The current heating periods are naturally considered in this case,<br />

if a time program was previously active.<br />

If the stove cools down too much meanwhile, then it reignites.<br />

= output level<br />

= temperature value<br />

(according to set operation mode)<br />

Press button<br />

SWITCHING OFF<br />

Step Description Display menu<br />

The fuel supply is interrupted, while the room air blower continues<br />

to be in operation for cooling the stove (displays “burnout”).<br />

During this burn-up phase, the flue gas blower also remains active<br />

for disposal of waste gases.