Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
6. Reference value table for presetting the heating system<br />
with <strong>Thermix</strong><br />
Quota under floor heating Total power of the heating system [kW] > 5 8 10 12 15 18<br />
V [l/min]<br />
UK<br />
T = 15 K<br />
T = 20 K<br />
4.3<br />
3.2<br />
6.9<br />
5.2<br />
<strong>8.</strong>6<br />
6.4<br />
10.3<br />
7.7<br />
12.9<br />
9.7<br />
15.5<br />
11.6<br />
up to 10%<br />
V [l/min]<br />
MK<br />
T = 15 K<br />
T = 20 K<br />
0.5<br />
0.4<br />
0.8<br />
0.6<br />
1.0<br />
0.7<br />
1.1<br />
0.9<br />
1.4<br />
1.1<br />
1.7<br />
1.3<br />
V [l/min]<br />
ges<br />
T = 15 K<br />
T = 20 K<br />
4.8<br />
3.6<br />
7.6<br />
5.7<br />
9.5<br />
7.2<br />
11.5<br />
<strong>8.</strong>6<br />
14.3<br />
10.7<br />
17.2<br />
12.9<br />
Pump level <strong>Thermix</strong> for the pumps 1.0 1.0 1.0 1.0 1.0 1.0<br />
V [l/min]<br />
UK<br />
T = 15 K<br />
T = 20 K<br />
3.6<br />
2.7<br />
5.7<br />
4.3<br />
7.2<br />
5.4<br />
<strong>8.</strong>6<br />
6.4<br />
10.7<br />
<strong>8.</strong>1<br />
12.9<br />
9.7<br />
up to 25%<br />
V [l/min]<br />
MK<br />
T = 15 K<br />
T = 20 K<br />
1.2<br />
0.9<br />
1.9<br />
1.4<br />
2.4<br />
1.8<br />
2.9<br />
2.1<br />
3.6<br />
2.7<br />
4.3<br />
3.2<br />
V [l/min]<br />
ges<br />
T = 15 K<br />
T = 20 K<br />
4.8<br />
3.6<br />
7.6<br />
5.7<br />
9.5<br />
7.2<br />
11.5<br />
<strong>8.</strong>6<br />
14.3<br />
10.7<br />
17.2<br />
12.9<br />
Pump level <strong>Thermix</strong> for the pumps 1.0 1.0 1.0 1.0 1.0 1.0<br />
V [l/min]<br />
UK<br />
T = 15 K<br />
T = 20 K<br />
2.4<br />
1.8<br />
3.8<br />
2.9<br />
4.8<br />
3.6<br />
5.7<br />
4.3<br />
7.2<br />
5.4<br />
<strong>8.</strong>6<br />
6.4<br />
up to 50%<br />
V [l/min]<br />
MK<br />
V [l/min]<br />
ges<br />
T = 15 K<br />
T = 20 K<br />
T = 15 K<br />
T = 20 K<br />
2.4<br />
1.8<br />
4.8<br />
3.6<br />
3.8<br />
2.9<br />
7.6<br />
5.7<br />
4.8<br />
3.6<br />
9.5<br />
7.2<br />
5.7<br />
4.3<br />
11.5<br />
<strong>8.</strong>6<br />
7.2<br />
5.4<br />
14.3<br />
10.7<br />
<strong>8.</strong>6<br />
6.4<br />
17.2<br />
12.9<br />
Pump level <strong>Thermix</strong> for<br />
4m - Pump<br />
6m - Pump<br />
1.0<br />
1.0<br />
1.0<br />
1.0<br />
1.0<br />
1.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
3.0<br />
2.0<br />
V [l/min]<br />
UK<br />
T = 15 K<br />
T = 20 K<br />
1.2<br />
0.9<br />
1.9<br />
1.4<br />
2.4<br />
1.8<br />
2.9<br />
2.1<br />
3.6<br />
2.7<br />
4.3<br />
3.2<br />
up to 75%<br />
V [l/min]<br />
MK<br />
V [l/min]<br />
ges<br />
T = 15 K<br />
T = 20 K<br />
T = 15 K<br />
T = 20 K<br />
3.6<br />
2.7<br />
4.8<br />
3.6<br />
5.7<br />
4.3<br />
7.6<br />
5.7<br />
7.2<br />
5.4<br />
9.5<br />
7.2<br />
<strong>8.</strong>6<br />
6.4<br />
11.5<br />
<strong>8.</strong>6<br />
10.7<br />
<strong>8.</strong>1<br />
14.3<br />
10.7<br />
12.9<br />
9.7<br />
17.2<br />
12.9<br />
Pump level <strong>Thermix</strong> for<br />
4m - Pump<br />
6m - Pump<br />
1.0<br />
1.0<br />
1.0<br />
1.0<br />
2.0<br />
2.0<br />
3.0<br />
2.0<br />
3.0<br />
2.0<br />
3.0<br />
3.0<br />
All data are reference values, deviations may be required according to the system used. The mixed heating circuit is taken into account with a<br />
pressure loss of 0.15 bar.<br />
V [l/min] = volumetric flow for unmixed circuit<br />
UK<br />
V [l/min] = volumetric flow for mixed circuit<br />
MK<br />
V [l/min] = total volumetric flow<br />
ges<br />
18<br />
GB