21<br />

Guideline value table for the presetting of the heating system with <strong>Thermix</strong><br />

Boiler circuit<br />

preliminary<br />

heat<br />

temperature<br />

unmixed<br />

heating circuit<br />

(°C)<br />

Preliminary<br />

heat<br />

temperature<br />

mixed<br />

heating circuit<br />

(°C)<br />

Spread for<br />

mixed<br />

heating<br />

circuit<br />

(K)<br />

Pressure<br />

loss mixed<br />

heating<br />

circuit<br />

(bar)<br />

pump setting of<br />

<strong>Thermix</strong>pumpe<br />

necessary volumetric flow of<br />

the boiler circuit<br />

(I/h)<br />

necessary pressure difference<br />

before <strong>Thermix</strong><br />

(from the boiler circuit)<br />

(bar)<br />

Achievement mixed heating circle (kW) 5 10 15 20 5 10 15 20 5 10 15 20<br />

65<br />

25<br />

30<br />

35<br />

40<br />

45<br />

50<br />

3<br />

5<br />

5<br />

7<br />

5<br />

7<br />

7<br />

10<br />

10<br />

15<br />

15<br />

20<br />

0.10 3 - - - 102 - - - 0.01 - - -<br />

0.15 3 - - - 102 - - - 0.01 - - -<br />

0.20 3 - - - 102 - - - 0.01 - - -<br />

0.10 1 3 - - 97 195 - - 0.01 0.02 - -<br />

0.15 2 3 - - 97 195 - - 0.01 0.02 - -<br />

0.20 2 - - - 97 - - - 0.01 - - -<br />

0.10 1 3 - - 110 219 - - 0.01 0.02 - -<br />

0.15 2 3 - - 110 219 - - 0.01 0.02 - -<br />

0.20 2 - - - 110 - - - 0.01 - - -<br />

0.10 1 2 3 - 104 209 313 - 0.01 0.02 0.07 -<br />

0.15 1 3 - - 104 209 - - 0.01 0.02 - -<br />

0.20 2 3 - - 104 209 - - 0.01 0.02 - -<br />

0.10 1 3 - - 125 251 - - 0.01 0.04 - -<br />

0.15 2 3 - - 125 251 - - 0.01 0.04 - -<br />

0.20 2 - - - 125 - - - 0.01 - -<br />

0.10 1 2 3 - 119 237 356 - 0.01 0.03 0.09 -<br />

0.15 1 3 - - 119 237 - - 0.01 0.03 - -<br />

0.20 2 3 - - 119 237 - - 0.01 0.03 - -<br />

0.10 1 2 3 - 137 274 411 - 0.01 0.05 0.13 -<br />

0.15 1 3 - - 137 274 - - 0.01 0.05 - -<br />

0.20 2 3 - - 137 274 - - 0.01 0.05 - -<br />

0.10 1 1 3 3 125 251 376 501 0.01 0.04 0.11 0.21<br />

0.15 1 2 3 3 125 251 376 501 0.01 0.04 0.11 0.21<br />

0.20 1 2 3 - 125 251 376 - 0.01 0.04 0.11 -<br />

0.10 1 1 3 3 146 292 438 585 0.01 0.06 0.15 0.31<br />

0.15 1 2 3 3 146 292 438 585 0.01 0.06 0.15 0.31<br />

0.20 1 2 3 - 146 292 438 - 0.01 0.06 0.15 -<br />

0.10 1 1 1 2 125 251 376 501 0.01 0.04 0.11 0.21<br />

0.15 1 1 2 2 125 251 376 501 0.01 0.04 0.11 0.21<br />

0.20 1 1 2 3 125 251 376 501 0.01 0.04 0.11 0.21<br />

0.10 1 1 1 2 146 292 438 585 0.01 0.06 0.15 0.31<br />

0.15 1 1 2 2 146 292 438 585 0.01 0.06 0.15 0.31<br />

0.20 1 1 2 3 146 292 438 585 0.01 0.06 0.15 0.31<br />

0.10 1 1 1 1 125 251 376 501 0.01 0.04 0.11 0.21<br />

0.15 1 1 1 2 125 251 376 501 0.01 0.04 0.11 0.21<br />

0.20 1 1 2 2 125 251 376 501 0.01 0.04 0.11 0.21<br />

All data are guideline values; depending on the system, deviations can occur = <strong>Thermix</strong> cannot be used. Guide-value tables for deviating<br />