Torque Limiters - LC SeriesLimiteurs de Couple - Série LCTorque Limiters Limiteurs de CoupleRotating shaftArbre tournantSELECTION GUIDE - MOUNTING RECOMMENDATIONSGUIDE DE SELECTION - CONSEILS DE MONTAGESelection guide / Guide de sélectionStandard sizing procedure1 - The rated torque of the unit selected must be greater thanthe highest torque required by the application (reductionratio -gears or belts- must be considered when making thecalculation).2 - The maximum heat generated by the application mustbe lower than the rated power dissipation of the specifiedtorque limiter.3 - The rated residual torque must be lower than the minimumrequested by the application (again, according toratio).For calculation details, please refer to pages 12 and 17Mounting recommendations / Conseils de montageProcedure de sélection usuelle1 - Le couple nominal du limiteur de couple choisi doit êtresupérieur à la valeur demandée la plus élevée (si nécessaire,prendre en compte les rapports de réduction -pignons oucourroies).2 - La puissance max. dissipée (couple et vitesse), doitdemeurer inférieure à celle indiquée sur les tableaux de donnéestechniques.3 - La valeur du couple résiduel doit être inférieure à celleimposée par l’application (en prenant là encore en comptele rapport de réduction).Pour tout détails de calculs, se référer à la page 12 et 17Elastic couplingAccouplementélastiqueNon-magnetic fixation flangeFlasque de fixation amagnétique FixedframeBati fixeElastic couplingAccouplementélastique89www.andantex.com