12.07.2015 Views

CRH-XHE 362-904 - Delta-Temp

CRH-XHE 362-904 - Delta-Temp

CRH-XHE 362-904 - Delta-Temp

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

BT08L005F--01<strong>362</strong> - <strong>904</strong>PRESTATIONS EN REFROIDISSEMENTRÉCUPÉRATION THERMODYNAMIQUE ACTIVE AVEC 45% D'AIR EXTERNE / EXPULSÉTAILLES<strong>362</strong>402452464524604704804<strong>904</strong>Qo(l/s)TEMPÉRATURE DE L'AIR DE REPRISE (D.B.) HUMIDITÉ RELATIVE D'AIR DE REPRISE14 °C 50% U.R. 16 °C 50% U.R. 18 °C 50% U.R. 20 °C 50% U.R. 22 °C 50% U.R.P (kW) Qa (l/s) P (kW) Qa (l/s) P (kW) Qa (l/s) P (kW) Qa (l/s) P (kW) Qa (l/s)2000 15,84 0,76 19,56 0,94 24,29 1,16 30,97 1,48 37,78 1,812500 18,49 0,88 22,86 1,09 27,74 1,33 35,42 1,69 43,18 2,073000 21,49 1,03 26,58 1,27 31,89 1,53 40,75 1,95 49,66 2,382200 17,42 0,83 21,51 1,03 26,72 1,28 34,07 1,63 41,55 1,992750 20,34 0,97 25,14 1,20 30,52 1,46 38,97 1,86 47,50 2,273250 23,28 1,11 28,80 1,38 34,55 1,65 44,15 2,11 53,80 2,572400 19,10 0,91 23,40 1,12 29,10 1,39 37,00 1,77 45,30 2,173000 22,40 1,07 27,50 1,32 33,40 1,60 42,50 2,03 52,10 2,493375 24,30 1,16 29,80 1,43 35,80 1,71 45,60 2,18 55,80 2,672875 22,77 1,09 28,12 1,35 34,92 1,67 44,53 2,13 54,31 2,60<strong>362</strong>5 26,82 1,28 33,15 1,59 40,23 1,92 51,37 2,46 62,62 3,004375 31,34 1,50 38,76 1,85 46,51 2,23 59,43 2,84 72,42 3,473250 25,74 1,23 31,78 1,52 39,47 1,89 50,33 2,41 61,40 2,944063 30,05 1,44 37,15 1,78 45,08 2,16 57,57 2,75 70,18 3,364875 34,92 1,67 43,19 2,07 51,82 2,48 66,22 3,17 80,70 3,86<strong>362</strong>5 28,72 1,37 35,45 1,70 44,03 2,11 56,15 2,69 68,49 3,284500 33,29 1,59 41,15 1,97 49,94 2,39 63,77 3,05 77,73 3,725250 37,61 1,80 46,52 2,23 55,81 2,67 71,32 3,41 86,91 4,164000 31,69 1,52 39,12 1,87 48,59 2,32 61,95 2,96 75,57 3,625000 36,99 1,77 45,72 2,19 55,48 2,65 70,85 3,39 86,37 4,135500 39,40 1,89 48,73 2,33 58,47 2,80 74,71 3,57 91,04 4,364500 35,65 1,71 44,01 2,11 54,66 2,62 69,70 3,33 85,01 4,075625 41,61 1,99 51,43 2,46 62,42 2,99 79,71 3,81 97,16 4,656625 47,46 2,27 58,70 2,81 70,43 3,37 90,00 4,31 109,67 5,255000 39,61 1,90 48,90 2,34 60,73 2,91 77,44 3,71 94,46 4,526250 46,23 2,21 57,14 2,73 69,35 3,32 88,56 4,24 107,95 5,177000 50,15 2,40 62,03 2,97 74,41 3,56 95,09 4,55 115,88 5,54Le tableau montre les avantages thermodynamique de récupération en termes de réduction de puissance échangée avec la source et la réduction de l'écoulementd'eau côté source (par exemple anneau WLHP). Lequel ne représente pas un accroissement de la puissance rendue de la machine, dont le rendement demeureessentiellement inchangé par rapport aux modèles sans cette option.Qo = débit d'air expulsé (l/s)P = puissance transmise côté entrée eau, dû à l‟échange thermique sur la batterie de récupération (anneau d'eau) en kWQa = réduction du débit d'eau due à l'échange thermique sur la batterie de récupération qui allège l'échangeur à plaques côté anneau d'eau (l/s)Les rendements de la récupération et le calcul de la réduction de débit d'eau se réfèrent à un anneau avec eau en entrée à l'échangeur de 15°C et en sortie de10°PRESTATION EN CHAUFFAGERÉCUPÉRATION THERMODYNAMIQUE ACTIVE AVEC 15% D'AIR EXTERNE / EXPULSÉTAILLES<strong>362</strong>402452464524604704804<strong>904</strong>Qo(l/s)TEMPÉRATURE DE L'AIR DE REPRISE (D.B.)22 °C 50% U.R. 25 °C 50% U.R. 27 °C 50% U.R. 28 °C 50% U.R. 30 °C 50% U.R.32 °C 50% U.R.P (kW) Qa (l/s) P (kW) Qa (l/s) P (kW) Qa (l/s) P (kW) Qa (l/s) P (kW) Qa (l/s) P (kW) Qa (l/s)667 26,24 1,26 25,22 1,21 24,22 1,16 23,80 1,14 22,90 1,10 22,03 1,05833 28,06 1,34 27,08 1,30 25,98 1,24 25,54 1,22 24,57 1,18 23,63 1,131000 31,14 1,49 30,13 1,44 28,89 1,38 28,39 1,36 27,31 1,31 26,27 1,26733 28,86 1,38 27,74 1,33 26,64 1,27 26,18 1,25 25,19 1,21 24,23 1,16917 30,87 1,48 29,79 1,43 28,59 1,37 28,09 1,34 27,03 1,29 25,99 1,241083 33,73 1,61 32,64 1,56 31,30 1,50 30,76 1,47 29,59 1,42 28,46 1,36800 31,45 1,50 30,21 1,45 29,05 1,39 28,49 1,36 27,43 1,31 26,36 1,261000 33,74 1,61 32,64 1,56 31,36 1,50 30,74 1,47 29,6 1,42 28,47 1,361125 34,97 1,67 33,82 1,62 32,48 1,55 31,83 1,52 30,65 1,47 29,44 1,41958 37,73 1,81 36,25 1,73 34,82 1,67 34,22 1,64 32,92 1,58 31,67 1,521208 40,69 1,95 39,28 1,88 37,68 1,80 37,03 1,77 35,63 1,70 34,26 1,641458 45,41 2,17 43,94 2,10 42,14 2,02 41,41 1,98 39,84 1,91 38,31 1,831083 42,64 2,04 40,98 1,96 39,36 1,88 38,68 1,85 37,21 1,78 35,80 1,711354 45,60 2,18 44,02 2,11 42,23 2,02 41,50 1,99 39,93 1,91 38,40 1,841625 50,60 2,42 48,97 2,34 46,95 2,25 46,14 2,21 44,39 2,12 42,69 2,041208 47,57 2,28 45,71 2,19 43,90 2,10 43,15 2,06 41,51 1,99 39,93 1,911500 50,51 2,42 48,75 2,33 46,78 2,24 45,97 2,20 44,22 2,12 42,53 2,041750 54,50 2,61 52,74 2,52 50,57 2,42 49,69 2,38 47,81 2,29 45,97 2,201333 52,49 2,51 50,44 2,41 48,44 2,32 47,61 2,28 45,80 2,19 44,06 2,111667 56,12 2,69 54,17 2,59 51,97 2,49 51,08 2,44 49,14 2,35 47,26 2,261833 57,09 2,73 55,25 2,64 52,98 2,53 52,06 2,49 50,08 2,40 48,16 2,301500 59,05 2,83 56,74 2,71 54,50 2,61 53,56 2,56 51,53 2,47 49,56 2,371875 63,14 3,02 60,94 2,92 58,47 2,80 57,46 2,75 55,28 2,65 53,17 2,542208 68,77 3,29 66,55 3,18 63,81 3,05 62,71 3,00 60,32 2,89 58,01 2,781667 65,61 3,14 63,05 3,02 60,55 2,90 59,51 2,85 57,25 2,74 55,07 2,632083 70,15 3,36 67,71 3,24 64,96 3,11 63,84 3,05 61,42 2,94 59,07 2,832333 72,66 3,48 70,32 3,36 67,43 3,23 66,26 3,17 63,74 3,05 61,30 2,93Le tableau montre les avantages thermodynamique de récupération en termes de réduction de puissance échangée avec la source et la réduction de l'écoulementd'eau côté source (par exemple anneau WLHP). Lequel ne représente pas un accroissement de la puissance rendue de la machine, dont le rendement demeureessentiellement inchangé par rapport aux modèles sans cette option.Qo = débit d'air expulsé (l/s)P = puissance transmise côté entrée eau, dû à l‟échange thermique sur la batterie de récupération (anneau d'eau) en kWQa = réduction du débit d'eau due à l'échange thermique sur la batterie de récupération qui allège l'échangeur à plaques côté anneau d'eau (l/s)Les rendements de la récupération et le calcul de la réduction de débit d'eau se réfèrent à un anneau avec eau en entrée à l'échangeur de 15°C et en sortie de10°33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!