68 7DN Mange personers indsats har været <strong>for</strong>udsætningen <strong>for</strong> at opnå de resultater, der her præsenteres og analyseres. Forfatterne ønsker specielt at takke Jesper Stubkjær, Steen Solvang Jensen, Ole Hertel, Matthias Ketzel, Keld Mortensen, Rosanna Bossi, Per Løfstrøm, Marianne Glasius, Lizzie Stausgård, Bjarne Jensen, Marlene Plejdrup og Morten Tranekjær Jensen. Alle de nævnte personer er eller har været ansat ved DMU.
5HIHUHQFHU EEA (2009): EMEP/EEA air pollutant emission inventory guidebook 2009. Technical guidance to prepare national emission inventories. EEA Technical Report 9/2009 Available at: http://www.eea.europa.eu/ publications/emep-eeaemission-inventory-guidebook-2009 Glasius, M., Ketzel, M., Wåhlin, P., Bossi, R., Stubkjær, J., Hertel, O. and F. Palmgren (2008). Characterization of particles from residential wood combustion and modelling of spatial variation in a low-strength emission area. Atmospheric Envirionment 42, 8686–8697. Glasius, M., Konggaard, P., Stubkjær, J., Bossi, R., Hertel, O., Ketzel, M., Wåhlin, P., Schleicher, O. & Palmgren, F. Danmarks Miljøundersøgelser (2007): Partikler og organiske <strong>for</strong>bindelser fra træfyring – nye undersøgelser af udslip og koncentrationer. Arbejdsrapport fra DMU, nr. 235. 42s. http://www.dmu.dk/Pub/AR235.pdf Glasius, M., Ketzel, M., Wahlin, P., Jensen, B., Monster, J., Berkowicz, R. and Palmgren, F. (2006). Impact of wood combustion on particle levels in a residential area in Denmark. Atmospheric Environment, 40, p.7115- 7124. Glasius, M., Vikelsøe, J., Bossi, R., Andersen, H.V., Holst, J., Johansen, E. & Schleicher, O. (2005): Dioxin, PAH og partikler fra Brændeovne. Danmarks Miljøundersøgelser. Arbejdsrapport fra DMU, nr. 212. 27 s. http://www.dmu.dk Illerup, J.B., Nielsen, O.K., Winther, M., Mikkelsen, M.H., Hoffmann, L., Nielsen, M., Gyldenkærne, S., Fauser, P. Jensen, M. T. & Bruun, H. G. (2007a): Annual Danish Emission Inventory Report to UNECE. Inventories from the base year of the protocols to year 2005. National Environmental Research Institute. - NERI Technical Report 649: 505 pp. http://person.au.dk/da/pub/12571272 Illerup, J.B., Henriksen, T.C., Lundhede, T., van Breugel, C. & Jensen, N.Z. (2007b): Brændeovne og små kedler – partikelemissioner og reduktions<strong>til</strong>tag. Miljøstyrelsen. - Miljøprojekt 1164: 46 s. (elektronisk). Illerup, J.B. and Nielsen, M. (2004): Improved PM emissions inventory <strong>for</strong> residential wood combustion. In: Dilara, P., Muntean, M., Angelino, E. (Eds): Proceedings of the PM Emission Inventories Scientific Workshop, Lago Maggiore, Italy, 18 October 2004. European Commission – EUR 21302: 142-149. Klippel, N, T. Nussbaumer (2007): Einfluss der Betriebsweise auf die Partikelemissionen von Holzöfen. Bundesamt fuer Energie, Bern, Switzerland, 63 p. www.verenum.ch/Publikationen/SBOfenmessun.pdf 69
- Page 1 and 2:
BRÆNDEFYRINGS BIDRAG TIL LUFTFORUR
- Page 3 and 4:
AU BRÆNDEFYRINGS BIDRAG TIL LUFTFO
- Page 5 and 6:
,QGKROG 6DPPHQIDWQLQJ 6XPPDU\ ,QGOH
- Page 7 and 8:
6DPPHQIDWQLQJ Rapporten redegør fo
- Page 9 and 10:
En begrænset undersøgelse af inde
- Page 11 and 12:
cles from wood combustion should be
- Page 13 and 14:
,QGOHGQLQJ Nærværende rapport gø
- Page 15 and 16:
1RJOH Y VHQWOLJH SRLQWHU I den offe
- Page 17 and 18:
Opgørelserne i Figur 2.1 viser at
- Page 19 and 20: LNNH frikendes. De indeholder bl.a.
- Page 21 and 22: )DOGJUXEH 0HGUHJQHV NRQGHQVHUEDUW V
- Page 23 and 24: 'DQVNH HPLVVLRQVIDNWRUHU Emissionsf
- Page 25 and 26: Som det vil fremgå af det følgend
- Page 27 and 28: Ã. Effekt af forskellige driftsfor
- Page 29 and 30: 5HVXOWDWHU IUD PnOHNDPSDJQHQ L 6ODJ
- Page 31 and 32: D E 0nOWH NRQFHQWUDWLRQHU Nogle hov
- Page 33 and 34: Regnet over hele perioden 23. decem
- Page 35 and 36: Perioden med målekampagnen var en
- Page 37 and 38: *HQHUDOLVHULQJ WLO nUVJHQQHPVQLW ±
- Page 39 and 40: ændefyr eller en brændekedel blev
- Page 41 and 42: flux er dermed 0,002 Nm 3/s (normal
- Page 43 and 44: den, men bliver mere pålidelige, n
- Page 45 and 46: 5 m skorsten, 4 m bygning 5 m skors
- Page 47 and 48: krævet for disse to typer ovne. De
- Page 49 and 50: D Ã Ã 80 60
- Page 51 and 52: over' med neddroslet lufttilførsel
- Page 53 and 54: skellige. Bemærk at der i Slagslun
- Page 55 and 56: Ã. Årsmiddelværdi af koncentrati
- Page 57 and 58: %U QGHI\ULQJV ELGUDJ L DQGUH GDQVNH
- Page 59 and 60: ÃÃÃÃÃÃÃ 400 300 Ã 200
- Page 61 and 62: ,QGHQG¡UV OXIWIRUXUHQLQJ IUD EU QG
- Page 63 and 64: 30 25 Ã 20 15 Ã 10
- Page 65 and 66: Enheden i tabellen er Mm -1. Som ti
- Page 67 and 68: RQNOXVLRQ YHGU LQGHQG¡UV IRUXUHQLQ
- Page 69: Det er en stor udfordring at fastl
- Page 73 and 74: 7RGRURYLþ J., H. Broden, N. Padban
- Page 75 and 76: Faglige rapporter fra DMU På DMU