Chapter 3<br />

Sampl<strong>in</strong>g sites and methods<br />

3.1 Setup of the sampl<strong>in</strong>g sites<br />

The sampl<strong>in</strong>g sites were chosen based on prelim<strong>in</strong>ary data <strong>by</strong> Schneider [2010] suggest<strong>in</strong>g high<br />

probabilities of oxygen depletion, there<strong>by</strong> be<strong>in</strong>g well suited to study whether oxygen depletion<br />

has any <strong>in</strong>fluence on noble gas partial pressures. Additionally, all sampl<strong>in</strong>g sites are <strong>in</strong> a reasonably<br />

close proximity to the Institute of Environmental <strong>Physics</strong>’ weather station as well as a<br />

weather station owned <strong>by</strong> the company meteomedia.<br />

3.1.1 Drill<strong>in</strong>g and <strong>in</strong>strumentation<br />

Drill<strong>in</strong>g the sample sites was done us<strong>in</strong>g a pneumatic pile hammer driven <strong>by</strong> a gas compressor.<br />

The pneumatic hammer was used to drive a hollow rod of 6 cm diameter and 1 m length <strong>in</strong>to<br />

the ground, allow<strong>in</strong>g for 1 m long, partly compressed core samples to be extracted, from which<br />

the soil layer structures were deduced. Us<strong>in</strong>g 1 m long solid extension rods the maximum depth<br />

reachable with the rented equipment was 9 m, however the maximum achieved depth was 5.9 m<br />

at Site A, 4.9 m at Site B and 2.9 m at Site C due to <strong>in</strong>creas<strong>in</strong>g friction at larger depths.<br />

Ground water tables were not reached at any of the sites. For simplification all soil air sampl<strong>in</strong>g<br />

depths are hereafter referred to <strong>by</strong> values rounded to the full meter.<br />

Sampl<strong>in</strong>g equipment, consist<strong>in</strong>g of three bundled TYGON R○ R-3603 Vacuum Tub<strong>in</strong>g tubes of<br />

different lengths and two LogTag TREX-8 temperature sensors, was lowered <strong>in</strong>to the boreholes.<br />

The tubes have an <strong>in</strong>ner diameter of 8 mm and were closed at their tips and perforated over a<br />

length of 10 cm <strong>by</strong> holes of 1 mm diameter (see Figure C.1). At 15 cm depth the tubes and sensor<br />

cables ran horizontally <strong>in</strong>to an underground box which was placed at a distance of about 20 cm<br />

to the hole, with a footpr<strong>in</strong>t of 0.03 m 2 , m<strong>in</strong>imally disturb<strong>in</strong>g the immediate site surround<strong>in</strong>gs.<br />

The boxes were covered <strong>by</strong> removable grass sods and conta<strong>in</strong>ed one LogTag TRIX-8 and two<br />

LogTag TREX-8 temperature data loggers as well as connectors and valves to access the different<br />

depth tubes. The sampl<strong>in</strong>g tubes were bundled <strong>in</strong>to a s<strong>in</strong>gle access tube, but rema<strong>in</strong>ed isolated<br />

from each other <strong>by</strong> valves, prevent<strong>in</strong>g contam<strong>in</strong>ation <strong>by</strong> backflow of atmospheric air.<br />

35