(7) The ductility factor of the braced frames which agree with the above<br />

items should be 2.0 in average or 1.5 considering the variation. The<br />

ductility factor of other types of braced frames should be 1.0.<br />

(8) It is possible to obtain the "q" value information from if the soil profile<br />

is determined.<br />

23-15-5 A Ceccotti, A Vignoli<br />

On a better evaluation of the seismic behavior factor of low-dissipative<br />

timber structures<br />

Summary<br />

Some results concerning the seismic verification of w-dissipation timber<br />

structures designed according to Eurocode assuming a behaviour factor q<br />

= 2 are given in this paper.<br />

The semi rigid connection design was performed considering suggestions<br />

given by the Authors in a previous paper.<br />

The numerical simulation was carried out using a time domain non linear<br />

dynamic analysis .<br />

Introduction<br />

Three kinds of timber structures are considered in the draft version of Eurocode<br />

8:<br />

– non-dissipative<br />

– low-dissipative<br />

– medium-dissipative.<br />

But due to the lack of knowledge the value of the behaviour fact reducing<br />

design inertia forces ("q") was fixed uniformly equal to 1 for each kind of<br />

structure.<br />

Conclusions<br />

From this research it seems possible to state that designing low dissipation<br />

semi-rigid connection portal frame timber structures following EC 5 and<br />

EC 8 rules but assuming q = 2 and using simple dimensioning rules for<br />

semi-rigid joints, it is possible to obtain structures whose resistance easily<br />

fulfils the Code strength requirements for seismic zones.<br />

23-15-7 M R O'Halloran, E G Elias<br />

Performance of timber frame structures during the Loma Prieta California<br />

earthquake<br />

Cib structural timber design code<br />

The <strong>CIB</strong> Timber Code provides for the development of design procedures<br />

for timber components and special structures. Section 7.4 is intended to<br />

provide specific provisions for the development of bracing requirements.<br />

Currently, the draft code does not contain references to either standard<br />

methods of test, sampling, or analysis of test data reporting wall bracing or<br />

diaphragm action.<br />

Objective<br />

The purpose of this paper is to present a review of the structural performance<br />

of timber frame buildings following the 1989 Loma Prieta earthquake.<br />

Results of this inspection reinforce the need for standardization in<br />

design of timber frame structures to resist seismic loading.<br />

Summary and conclusions<br />

A team of engineers from the American Plywood Association<br />

(APA)visited the San Francisco Bay area shortly following the Loma Prieta<br />

earthquake of October 17, 1989. Damage from the earthquake occurred<br />

in scattered locations within the region. Within these locations, the heaviest<br />

damage appeared to be to buildings with unreinforced masonry walls.<br />

All observed wood-framed buildings which were damaged were either<br />

built before the 1973 Uniform Building Code introduced updated earthquake<br />

regulations, or incorporated critical construction features but with<br />

inadequate connections, or other features which were not nailed or stapled<br />

in accordance with minimum code requirements.<br />

It is the conclusion of the APA team of observers that framed construction<br />

built to meet current provisions of the Uniform Building Code performed<br />

very well. No code deficiencies for this type of construction were<br />

observed. However, greater attention must be paid to design and installation<br />

of connections and fastenings, and to structural continuity, especially<br />

in small buildings which may not be engineered.<br />