Conclusion<br />

Summarizing the results of this study, the following conclusions are lead.<br />

(1) Double shear bolted joints with the steel plates placed on the side of<br />

the beam and those with the steel plate inserted in the beam showed<br />

very brittle failure. Stress distribution in the direction perpendicular to<br />

the grain should be considered to design this type of joint.<br />

(2) Single shear bolted joints with the steel plates placed on the edge of<br />

the beam showed relatively high ductility. However the joints having<br />

large numbers of bolts or lag screws showed less ductility.<br />

(3) The joint in which pre-stress was applied with the steel rods did not<br />

fail at the deflection of 30 centimeters, and showed high ductility.<br />

(4) The hysteresis loops of the joints were different according to the types<br />

of the joint. Initial slips caused by the clearance of the bolt holes were<br />

remarkable.<br />

(5) The equivalent viscous damping of the mechanical joints in which<br />

neither adhesives nor tensile bolts were used was approximately 5 to<br />

12 % when the deflection was small. This relatively high viscous<br />

damping may be caused by the initial slips of the joints.<br />

(6) The equivalent viscous damping of the joint was approximately 2 % at<br />

the deflection of 1/100 of a span, and it increased to approximately 5<br />

% in plastic area.<br />

(7) Initial rotational angle of the joint in which neither adhesives nor tensile<br />

bolts were used varied from 1/350 to 1/130 and the rotational<br />

stiffness of the joint was about a half of those calculated from the experiment<br />

of one bolt.<br />

(8) Ductility factors of the joint with the steel plates placed on the edge of<br />

the beam were 4.3 and 4.8 respectively, and that of the joint in which<br />

the steel plate was inserted and connected with twenty drift pins per<br />

joint was 3.2. Other types of joints showed brittle performance except<br />

for the specimen in which the pre-stress was applied on the steel rods.<br />

22-15-5 M Yasumura<br />

Seismic behaviour of arched frames in timber construction<br />

Introduction<br />

Arched frames of glued-laminated timber have been used widely in large<br />

scale construction. As the vertical loads such as the lead load and the snow<br />

load are generally more critical than the lateral loads in the large span<br />

structure, few studies have been done on the seismic behavior of the<br />

arched frames. In the previous paper, Paper 22-7-7, the mechanical properties<br />

of the joints in glued laminated beams subjected to the reversed cyclic<br />

loads were investigated. In this study, the arched frames of the glued<br />

laminated timber having the joints in the principal rafters were subjected<br />

to the reversed cyclic lateral loads, and the mechanical properties of the<br />

frames were investigated.<br />

Time-history earthquake response of the three-hinged frames vas obtained<br />

from the linear model and the bi-linear elastic model, and the influence<br />

of joints of the principal rafters on the seismic behavior of the frame<br />

was also studied in this paper.<br />

Conclusions<br />

Summarizing the results of this study, the following conclusions are lead.<br />

(1) Three specimens among four failed with the radial stress at the curved<br />

part of the glued-laminated wood, and one failed with the yield of a<br />

steel plate connecting the principal rafters. Both kinds of failures were<br />

not expected when the specimens were designed, and the difference of<br />

the safety factors among the steel, wood and mechanical joints should<br />

be considered in case of the design procedure.<br />

(2) In three-hinged frames having the joints in the principal rafters, particular<br />

effect of the initial slips of the joint was observed. This effect<br />

might be caused by the difference of the moment distribution in the<br />

right and left joints, and this effect was small in two-hinged frame.<br />

(3) The equivalent viscous damping of the three-hinged frames having the<br />

joints in the principal rafters was 2 to 3% when the deformation was<br />

small, and it coincided with the equivalent viscous damping obtained<br />

from the experimental results of the joints.<br />

(4) The equivalent viscous damping of the three-hinged frame having no<br />

joints in the principal rafters was approximately 1%, and showed low<br />

damping capacity.<br />

(5) The equivalent viscous damping of the frame after the failure of the<br />

glued-laminated timber by the radial stress at the curved part increased<br />

to approximately 4%.<br />

(6) The maximum load of each frame was 74.6 to 78.0 kN regardless of<br />

the types of joint. The maximum radial stress calculated from the<br />

maximum load was approximately 96.6 kN/cm 2 .<br />