short and precise. It is necessary and shall be possible to estimate realistically<br />

the stiffness and deformation properties with all timber-related scatter.<br />

To give the background information is the duty of conferences like this<br />

<strong>CIB</strong>-meeting and the Universities.<br />

The formulation of several parts depends on the regulations in other<br />

parts of Eurocode 8 (e.g. the regularity-classes or the damping ratios), Eurocode<br />

5 (e.g. design rules for nails) or other corresponding codes. As long<br />

as these codes are still in revision, redrafting or anyhow not in their final<br />

version some provisions may be changed.<br />

The code requirements are mainly pointed on the attempt to provide<br />

sufficient ductile and hysteretic mechanisms in the structure. In opposite to<br />

other materials like concrete, steel and composite structures the ductility is<br />

mainly located in the connections, as the material itself shows in most cases<br />

a brittle behaviour.<br />

The following pages will contain the code text. At text parts or pictures,<br />

which took more effort to formulate in the pertinent way, information and<br />

justification notes are given in boxes.<br />

26-15-3 M R O'Halloran, E L Keith, J D Rose, T P Cunningham<br />

Hurricane Andrew - Structural performance of buildings in south Florida<br />

Abstract<br />

This report describes the structural performance of residential and low-rise<br />

commercial structures in South Florida, based on observations from onsite<br />

inspections conducted within one week after Hurricane Andrew struck<br />

the Miami region on August 24, 1992. All types of construction – concrete,<br />

masonry, steel and wood – were inspected by a 45-member task<br />

group including a team of three technical and field promotion staff members<br />

from the American Plywood Association. The report concentrates<br />

primarily on the observed performance of wood systems, but other types<br />

of construction also are covered. Observations and conclusions are presented<br />

dealing with roofing attachment; wood structural panel roof sheathing<br />

-both plywood and oriented strand board (OSB) – and its attachment to<br />

framing and gable-end roof systems in particular; walls and connections of<br />

components; attachment of metal roof deck panels to steel framing; connections<br />

between concrete and metal roof decks and concrete or masonry<br />

walls; and attachment of cladding for pre-engineered metal buildings.<br />

This report also provides a review of work completed which recommended<br />

fastening schedules for oriented strand board and plywood roof<br />

sheathing. The recommended schedules were established to provide resistance<br />

to wind uplift pressure, with particular emphasis on high-wind<br />

exposures. The approach included laboratory testing, engineering and<br />

computer analysis.<br />

Conclusions<br />

As can be seen from the observations discussed above, much of the structural<br />

damage done to the structures in South Florida was preventable<br />

through the proper design, specification and execution of connections between<br />

structural elements. It is hoped that, through publications such as<br />

this, knowledge of the importance of making proper connections can be<br />

conveyed to the building industry to eliminate the possibility of such preventable<br />

tragedies in the future. While it is difficult to imagine a natural<br />

disaster greater than Hurricane Andrew, it would be an even greater tragedy<br />

if we did not learn from the experience.<br />

29-15-2 M Yasumura, N Kawai, N Yamaguchi, S Nakajima<br />

Damage of wooden buildings caused by the 1995 Hyogo-Ken Nanbu<br />

earthquake<br />

Introduction<br />

A strong earthquake occurred in Hanshin area in the early morning of 17<br />

January, 1996. It caused the largest scale of damages since after the Second<br />

World War. Over 6,300 persons were killed or lost, over 43,000 persons<br />

were injured and about 400,000 buildings were damaged. A large<br />

number of fatalities were caused by the collapse of wooden houses. Building<br />

Research Institute conducted a survey on the damaged wooden houses<br />

due to the 1995 Hyogo-ken Nanbu earthquake. This report presents the<br />

outline of the damages of wooden houses and discusses the aseismic design<br />

of timber structures in Japan.<br />

<strong>CIB</strong>-<strong>W18</strong> Timber Structures – A review of meeting 1-43 5 SPECIAL ACTIONS page <strong>5.1</strong>3