127083-Y<strong>IM</strong>-B-0606<br />
This product must be installed in strict compliance with<br />
the enclosed installation instructions <strong>and</strong> any applicable<br />
local, state <strong>and</strong> national codes including, but not<br />
limited to, building, electrical, <strong>and</strong> mechanical codes.<br />
The furnace <strong>and</strong> its individual shut-off valve must be<br />
disconnected from the gas supply piping system during<br />
any pressure testing at pressures in excess of 1/2<br />
PSIG.<br />
Pressures greater than 1/2 PSIG will cause gas valve<br />
damage resulting in a hazardous condition. If it is subjected<br />
to a pressure greater than 1/2 PSIG, the gas<br />
valve must be replaced.<br />
The furnace must be isolated from the gas supply piping<br />
system by closing its individual manual shut-off<br />
valve during any pressure testing of the gas supply piping<br />
system at test pressures equal to or less than 1/2<br />
PSIG.<br />
L<strong>IM</strong>ITATIONS<br />
These units must be installed in accordance with the following:<br />
In U.S.A.:<br />
1. National <strong>Electric</strong>al Code, ANSI/NFPA No. 70 - Latest<br />
Edition<br />
2. National Fuel <strong>Gas</strong> Code, ANSI Z223.1 - Latest Edition<br />
3. <strong>Gas</strong>-Fired Central Furnace St<strong>and</strong>ard, ANSI Z21.47a. -<br />
Latest Edition<br />
4. Local building codes, <strong>and</strong><br />
5. Local gas utility requirements<br />
In Canada:<br />
1. Canadian <strong>Electric</strong>al Code, CSA C22.1<br />
2. Installation Codes, CSA - B149.1.<br />
3. Local plumbing <strong>and</strong> waste water codes, <strong>and</strong><br />
4. Other applicable local codes.<br />
Refer to Tables 1 & 2 for unit application data.<br />
After installation, gas fired units must be adjusted to obtain a<br />
temperature rise within the range specified on the unit rating<br />
plate.<br />
If components are to be added to a unit to meet local codes,<br />
they are to be installed at the dealer’s <strong>and</strong>/or customer’s<br />
expense.<br />
Size of unit for proposed installation should be based on heat<br />
loss/heat gain calculation made according to the methods of<br />
Air Conditioning Contractors of America (<strong>AC</strong>CA).<br />
This furnace is not to be used for temporary heating of buildings<br />
or structures under construction.<br />
Unitary Products Group 9