EXTERIOR<br />
FACTORY<br />
BUILT<br />
CHIMNEY<br />
NOTE:<br />
Exterior<br />
chimneys are<br />
subject to<br />
greater<br />
moisture and<br />
creosote<br />
accumulation<br />
due to the<br />
lower<br />
temperatures.<br />
An insulated<br />
chase will<br />
reduce these<br />
accumulations<br />
(the proper<br />
clearances to<br />
the chimney<br />
must be<br />
maintained).<br />
HEARTH<br />
STOVE<br />
POSITIVE<br />
CONNECTION<br />
NOTE:<br />
Most factorybuilt<br />
chimney<br />
manufacturers<br />
make stainless<br />
steel chimney<br />
liners, either<br />
flexible or<br />
rigid. This<br />
provides a<br />
wide variety of<br />
installation<br />
options. Make<br />
sure to follow<br />
the<br />
manufacturer's<br />
instructions for<br />
installation<br />
and support.<br />
Chimney Cap<br />
(See the section "Chimney<br />
Termination Requirements"<br />
for more details)<br />
Chimney Sections<br />
Minimum Air Space to<br />
Combustibles (See<br />
Chimney Manufacturer's<br />
Instructions - usually 2")<br />
Min. 18" clearance<br />
to ceiling<br />
Chimney Connector<br />
Sections<br />
Floor Protection<br />
(See the<br />
section "Floor<br />
Protection<br />
Requirements"<br />
for more<br />
details)<br />
Combustible<br />
Mantle<br />
Wall Bands<br />
and Supports<br />
NOTE: The entire fireplace,<br />
including chimney, must be clean<br />
and not cracked or damaged.<br />
Any damage must be repaired<br />
prior to installation of the insert.<br />
Chimney must be at least 15' tall<br />
and no greater than 33' tall.<br />
Entire fireplace, including<br />
chimney, must meet local<br />
building requirements.<br />
Floor Protection<br />
(See the section<br />
"Floor Protection<br />
Requirements"<br />
for more details)<br />
Min. 18"<br />
STOVE INSTALLATION (CONT.) PAGE 13<br />
} }<br />
}<br />
Follow the chimney<br />
manufacturer's<br />
instructions and<br />
clearances for roof<br />
penetrations. A storm<br />
collar and flashing are<br />
required (some require<br />
a radiation shield).<br />
Minimum 15'<br />
Maximum 33'<br />
You should have at<br />
least 8' of vertical<br />
chimney for every 1'<br />
of horizontal run.<br />
Insulated Tee<br />
Follow the chimney<br />
manufacturer's<br />
instructions and<br />
clearances for wall<br />
penetrations. A wall<br />
radiation shield<br />
(thimble) is required.<br />
Stove Clearances<br />
(See the section "Stove<br />
Placement Requirements" Optional<br />
for more details)<br />
insulated chase<br />
Cap (prevents water<br />
from entering)<br />
Flue Liner<br />
The liner must be<br />
stainless steel connector<br />
or flexible vent. Follow<br />
the liner manufacturer's<br />
instructions for<br />
installation and support.<br />
Airtight Insulated<br />
Clean-Out<br />
Remove damper<br />
or wire it open<br />
See the section<br />
"Stove Placement<br />
Requirements" for<br />
minimum clearances<br />
required.