EXTERIOR<br />

FACTORY<br />

BUILT<br />

CHIMNEY<br />

NOTE:<br />

Exterior<br />

chimneys are<br />

subject to<br />

greater<br />

moisture and<br />

creosote<br />

accumulation<br />

due to the<br />

lower<br />

temperatures.<br />

An insulated<br />

chase will<br />

reduce these<br />

accumulations<br />

(the proper<br />

clearances to<br />

the chimney<br />

must be<br />

maintained).<br />

HEARTH<br />

STOVE<br />

POSITIVE<br />

CONNECTION<br />

NOTE:<br />

Most factorybuilt<br />

chimney<br />

manufacturers<br />

make stainless<br />

steel chimney<br />

liners, either<br />

flexible or<br />

rigid. This<br />

provides a<br />

wide variety of<br />

installation<br />

options. Make<br />

sure to follow<br />

the<br />

manufacturer's<br />

instructions for<br />

installation<br />

and support.<br />

Chimney Cap<br />

(See the section "Chimney<br />

Termination Requirements"<br />

for more details)<br />

Chimney Sections<br />

Minimum Air Space to<br />

Combustibles (See<br />

Chimney Manufacturer's<br />

Instructions - usually 2")<br />

Min. 18" clearance<br />

to ceiling<br />

Chimney Connector<br />

Sections<br />

Floor Protection<br />

(See the<br />

section "Floor<br />

Protection<br />

Requirements"<br />

for more<br />

details)<br />

Combustible<br />

Mantle<br />

Wall Bands<br />

and Supports<br />

NOTE: The entire fireplace,<br />

including chimney, must be clean<br />

and not cracked or damaged.<br />

Any damage must be repaired<br />

prior to installation of the insert.<br />

Chimney must be at least 15' tall<br />

and no greater than 33' tall.<br />

Entire fireplace, including<br />

chimney, must meet local<br />

building requirements.<br />

Floor Protection<br />

(See the section<br />

"Floor Protection<br />

Requirements"<br />

for more details)<br />

Min. 18"<br />

STOVE INSTALLATION (CONT.) PAGE 13<br />

} }<br />

}<br />

Follow the chimney<br />

manufacturer's<br />

instructions and<br />

clearances for roof<br />

penetrations. A storm<br />

collar and flashing are<br />

required (some require<br />

a radiation shield).<br />

Minimum 15'<br />

Maximum 33'<br />

You should have at<br />

least 8' of vertical<br />

chimney for every 1'<br />

of horizontal run.<br />

Insulated Tee<br />

Follow the chimney<br />

manufacturer's<br />

instructions and<br />

clearances for wall<br />

penetrations. A wall<br />

radiation shield<br />

(thimble) is required.<br />

Stove Clearances<br />

(See the section "Stove<br />

Placement Requirements" Optional<br />

for more details)<br />

insulated chase<br />

Cap (prevents water<br />

from entering)<br />

Flue Liner<br />

The liner must be<br />

stainless steel connector<br />

or flexible vent. Follow<br />

the liner manufacturer's<br />

instructions for<br />

installation and support.<br />

Airtight Insulated<br />

Clean-Out<br />

Remove damper<br />

or wire it open<br />

See the section<br />

"Stove Placement<br />

Requirements" for<br />

minimum clearances<br />

required.