Conduct the items shown under 25, 50 and 100 Hour Checks.<br />

<strong>Jabiru</strong> 3300 <strong>Aircraft</strong> Engine<br />

Hydraulic Valve Lifter Models<br />

5.8 Engine Overhauls<br />

The Overhaul Manual for the <strong>Jabiru</strong> 2200 and 3300 engines must be referred to for engine<br />

overhaul procedures.<br />

The overhaul work must be carried out to <strong>Jabiru</strong> specifications at an approved aeronautical<br />

service facility or by an approved <strong>Jabiru</strong> Service Centre.<br />

If necessary, changes to the TBO Limit due to operational experience, will be announced by<br />

<strong>Jabiru</strong> in a Service Bulletin.<br />

5.9 Engine Preservation<br />

The following procedures assume that the engine is installed in a <strong>Jabiru</strong> airframe. For other aircraft<br />

types, refer to the manufacturer's service manual. If the engine is not fitted to an airframe, ignore<br />

those items referring to the airframe.<br />

Note: Failure to store the engine for a long period of time, in excess of 90 days, without taking the<br />

preventative measures as outlined in the manual will affect claims upon <strong>Jabiru</strong>‟s Limited, Express<br />

Warranty.<br />

5.9.1 Flyable Storage<br />

Flyable storage is defined as a maximum of 30 days non-operational storage.<br />

Ensure that the engine has been stopped by turning off the fuel valve, thereby not leaving any<br />

fuel in the carburettor bowl.<br />

Every 7 th day the propeller should be rotated through 5 revolutions, without running the engine.<br />

Leave the propeller in the horizontal position to ensure even distribution of liquids in the wood. If<br />

left in the vertical position, liquids will drain to the lower tip resulting in an unbalanced propeller.<br />

Note that intake & exhaust covers should be removed before performing this task.<br />

CAUTION<br />

Ensure that the Master and Ignition Switches are OFF before turning engine!<br />

5.9.2 Returning Engine to Service From Flyable Storage<br />

After flyable storage, returning the engine to service is accomplished by performing a thorough<br />

pre-flight inspection. Ensure all protective covers are removed.<br />

5.9.3 Temporary Storage<br />

Temporary storage is defined as aircraft in non-operational status for a maximum of 90 days<br />

(nominal – depending on ambient temperature, humidity etc).<br />

Treat as for flyable storage (see Paragraph 5.9.1), plus:<br />

For temporary storage, fill fuel tank with correct grade of fuel (to prevent moisture<br />

accumulation).<br />

This document is controlled while it remains on the <strong>Jabiru</strong> server. Once this no longer applies the document becomes uncontrolled.<br />

REVISION 0 1 2 3 4 5 6 7 8 9 Dated : Apr 2011 Issued By: DPS Page: 19 of 53<br />