DIESEL<br />
PROPERTY UNITS<br />
METHODOLOGY GUIDE APPENDIX<br />
50 ULSD cargoes EN590 cargoes ULSD cargoes 10 cargoes and ULSD barges ARA<br />
NWE and Med NWE and MED NWE barges<br />
SULFUR Parts per Million 50 max 350 max 50 max 10 max 50 max<br />
DENSITY At 15 deg C Kg/m3 0.820-0.845 0.820-0.845 0.820-0.835 0.820-0.845 0.820-0.845<br />
CETANE INDEX NUMBER 46 min 46 min 46 min 46 min 46 min<br />
CLOUD<br />
Winter Deg C -5 max -5 max -5 max -7 max -7 max (*1)<br />
Intermediate -3 max 0 max<br />
Summer 5 max 5 max 3 max 5 max 4 max<br />
CFFP POINT<br />
Winter Deg C -15 max -15 max -15 max -22 max -20 max<br />
Intermediate -13 max -11 max<br />
Summer 0 max 0 max -5 max -2 -5 max<br />
DISTILLATION<br />
Recovered at % Vol<br />
250 deg C 65 max 65 max 65 max 64 max 64 max<br />
345 deg C 95 min<br />
350 deg C 85 min 85 min 85 min 85 min<br />
360 deg C 95 min 95 min 95 min<br />
370 deg C<br />
FLASH POINT Deg C 55 min 55 min 60 min (*1) 56 min (*3) 56 min<br />
120 max 120 max<br />
VISCOSITY At 40 deg C 2 to 4.5 2 to 4.5 2 to 4.5 2 to 4.5 2 to 4.5<br />
(*1)-5 cloud is often traded, if effective WASA available, minimum 150ppm, as part of an industry agreement<br />
(*2) 55 min is the standard flash, but tends to be 60 flash min in practice.<br />
(*3) 10ppm barges can reflect 59 min flash point for pipeline grade, but not barge<br />
GASOIL<br />
GERMAN Cargo DIN FRENCH FOD RUSSIAN<br />
and barge<br />
PROPERTY UNITS<br />
SULFUR Parts per million 2000 2000 2000<br />
DENSITY Kg/m3 Assessed basis Assessed basis Assessed basis<br />
0.845 0.845 0.845<br />
CETANE INDEX Standard calorific 40 min 45 min, but<br />
value 42.6 MJ/KG typically tends to be<br />
more than 50<br />
CLOUD Deg C 1 max (a) 2 max -5 max<br />
2 max (b)<br />
3 max (c)<br />
CFPP POINT Deg C -10 max (a) - 5 max -7 typical<br />
-11 max (b)<br />
-12 max ©<br />
DISTILLATION % Vol<br />
Recovered at<br />
280 deg C 65 max 65 max 50 max<br />
360 deg C 85 min 85 min 96 min<br />
FLASH POINT Deg C 55 min (*4) 55 min<br />
62 min<br />
VISCOSITY<br />
At 20 deg C 3 to 6<br />
At 40 deg C 2 to 6 2 to 4.5<br />
(*4) German DIN official is 55 min flash, but the requirements is sometimes higher in the cargo market, 57 min flash.<br />
TEST METHOD<br />
French FOD and German DIN test method is based on standard European test methods.<br />
Russian gasoil test method is GOST<br />
EUROPEAN PRODUCTS<br />
57<br />
APPENDIX III TYPICAL MIDDLE DISTILLATE QUALITIES<br />
These specifications represent a guideline, but are not Platts specifications. Platts assesses the typical grades in the market.