DESIGN CHARTS<br />

General<br />

Vertical load on wall<br />

Structural system:<br />

M1 BSP crossplan wall<br />

under vertical load;<br />

R30 / one-sided<br />

Version 1 / 2011<br />

perm. load N k [kN / m]<br />

900,0<br />

800,0<br />

700,0<br />

600,0<br />

500,0<br />

400,0<br />

300,0<br />

200,0<br />

100,0<br />

0,00<br />

1,00 m<br />

2,00 m<br />

M1 BSP crossplan<br />

The tables referred to serve for the preliminary design and do not replace a structural calculation.<br />

• Determination of the permissible vertical load N in relation to 1,0 m wall width.<br />

• Wall pillars must be considered separately<br />

• Load assumptions - wind load: 1,0 kN / m²<br />

• Classifi cation REI 30 / one-sided<br />

• EI according to classifi cations<br />

h<br />

w k = 1,0 kN/m<br />

zul N k<br />

Top layer in vertical direction<br />

max 3,00 m<br />

max 16,50 m<br />

95 5S DQ 98 3S DQ 118 3S DQ 134 5S DQ 146 5S DQ 160 5S DQ<br />

Wall height<br />

2,50 m<br />

3,00 m<br />