05.10.2012 Views

Broch

Broch

Broch

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

M1 BSP crossplan<br />

IW 01<br />

inside inside<br />

IW 02<br />

inside inside<br />

FD 01<br />

outside<br />

inside<br />

FD 02<br />

outside<br />

inside<br />

28 Mayr-Melnhof Kaufmann<br />

Interior wall / without service layer<br />

Wall cross-section from<br />

outside to inside<br />

Interior wall / without service layer<br />

CONSTRUCTION DETAILS<br />

WALL CONSTRUCTION<br />

Thickness<br />

mm<br />

Overall<br />

thickness mm<br />

Flat roof / suspended / without rear ventilation<br />

Flat roof / suspended / without rear ventilation<br />

Fire<br />

protection<br />

M1 BSP crossplan 95,0 95 REI 60*<br />

Wall cross-section from<br />

outside to inside<br />

Wall cross-section from<br />

outside to inside<br />

Thickness<br />

mm<br />

Gravel fi ll<br />

Separating fl eece [Sd ≤ 0,2M]<br />

50,0<br />

Extruded polystyrene 80,0<br />

Bituminous cardboard 9,0<br />

Rockwool [0,040; R = 16]<br />

Vapour barrier Sd ≥ I500M<br />

150,0<br />

M1 BSP crossplan ceiling or<br />

acc. to structural requirement<br />

140<br />

Timber spruce battens suspended<br />

Glasswool [0,040; R = 16] d = 50 mm<br />

70,0<br />

Gypsum fi breboard 12,5<br />

Wall cross-section from<br />

outside to inside<br />

Thickness<br />

mm<br />

Gypsum fi breboard 1 x 12,5 mm 25,0<br />

M1 BSP crossplan 78,0<br />

Gypsum fi breboard 1 x 12,5 mm 25,0<br />

Thickness<br />

mm<br />

Roofi ng membrane<br />

Fibre insulation board 2 x 100 mm 200,0<br />

Vapour barrier bituminous<br />

(= emergency roof)<br />

M1 BSP crossplan<br />

0,2<br />

Ceiling 118 mm or according<br />

to structural requirement<br />

118<br />

Bracket / air space 50,0<br />

Gypsum fi breboard 12,5<br />

Overall<br />

thickness mm<br />

Overall<br />

thickness mm<br />

Fire<br />

protection<br />

512 REI 90*<br />

Overall<br />

thickness mm<br />

* according classifi cation reports M1 BSP crossplan of HFA<br />

Fire<br />

protection<br />

128 REI 60*<br />

Fire<br />

protection<br />

381 REI 60*<br />

Sound<br />

insulation<br />

Airborne noise<br />

R W 33 dB<br />

Sound<br />

insulation<br />

Airborne noise<br />

R W 38 dB<br />

Source: www.dataholz.com, catalogue «Bauphysikalisch geprüfter Bauteile für den Holzbau»<br />

Sound<br />

insulation<br />

Airborne<br />

noise<br />

R W 47 dB<br />

Sound<br />

insulation<br />

Airborne<br />

noise<br />

R W 47 dB<br />

Thermal<br />

insulation<br />

U value<br />

1,1 [W / m 2 K]<br />

Thermal<br />

insulation<br />

U value<br />

0,87 [W / m 2 K]<br />

Thermal<br />

insulation<br />

U value<br />

0,12 [W / m 2 K]<br />

Thermal<br />

insulation<br />

U value<br />

0,15 [W / m 2 K]<br />