M1 BSP crossplan<br />

Product<br />

Lay-up and production<br />

Dimensions<br />

Technical approvals<br />

Types of wood<br />

Lamellas<br />

Strength classes<br />

(lamellas)<br />

Gluing<br />

Density<br />

Moisture content<br />

Dimensional stability<br />

Thermal conductivity<br />

Heat capacity<br />

Water vapour<br />

resistance factor<br />

Airtightness<br />

Sound insulation<br />

Reaction to fi re<br />

Charring rate<br />

Service classes<br />

6 Mayr-Melnhof Kaufmann<br />

TECHNICAL DATA<br />

M1 BSP crossplan is a large-format, solid timber panel (cross-laminated timber panel) with<br />

multi-layered, crosswise laminated lay-up.<br />

Finger-jointed and planed lamellas are loosely laid next to each other and the fl at surfaces of<br />

the layers glued at right angles to one another.<br />

To avoid uncontrolled stress cracks, the narrow sides are not edge-glued.<br />

The layers are pushed laterally to dimension before applying the pressure (1,2 N/mm 2 ) in<br />

order to obtain a gap-free surface.<br />

Lengths to 16,50 m<br />

Widths to 3,00 m<br />

Thicknesses 57 to 278 mm<br />

European technical approval ETA−09 / 0036<br />

German technical approval Z-9.1-638<br />

Spruce (Picea abies) from domestic forests; other wood species on request<br />

19 to 40 mm, kiln-dried, quality graded and fi nger-jointed<br />

C 24 acc. to EN 338 (equivalent to S 10 acc. to DIN 4074)<br />

A proportion of max. 10 % C 16 is permissible (ETA-09 / 0036)<br />

Melamine resin-based adhesive, Adhesive Type I acc. to EN 301 approved for the gluing of<br />

load-bearing timber components, for both interiors and exteriors, weather-resistant with<br />

transparent glued joint<br />

Approx. 480 kg / m 3<br />

12 % (+ / - 2 %) on delivery<br />

II to panel plane 0,01 % per % change in moisture content<br />

⊥ to panel plane 0,20 % per % change in moisture content<br />

λ = 0,13 W / mK<br />

c = 1,60 kJ / kgK<br />

μ = 60 (at 12 % moisture content)<br />

Airtight from a panel thickness of 95 mm<br />

Dependent on wall or ceiling build-up � see tested sample wall constructions<br />

According EN 13501: D, s2, d0<br />

(standard infl ammability, average smoke emission, no combustible drips)<br />

Fire resistance according to classifi cation report of HFA, EN 13501-2 REI 30 to REI 120<br />

Wall: 0,64 mm/min<br />

Ceiling: 0,71 mm/min<br />

1 or 2 acc. to ETA-03 / 0036<br />

Standard widths 2,40 m / 2,65 m / 2,75 m /<br />

2,90 m / 3,00 m<br />

Version 1 / 2011