M1 BSP crossplan<br />

AW 01<br />

I<br />

outside inside<br />

AW 02<br />

outside inside<br />

AW 03<br />

outside inside<br />

AW 04<br />

outside inside<br />

26 Mayr-Melnhof Kaufmann<br />

Wall cross-section from<br />

outside to inside<br />

CONSTRUCTION DETAILS<br />

WALL CONSTRUCTION<br />

Thickness<br />

mm<br />

Timber larch cladding 20,0<br />

Timber spruce battens (30 / 60) 30,0<br />

Vapour-permeable membrane<br />

Sd ≤ 0,3 m<br />

–<br />

Wood fi bre insulation board 100,0<br />

M1 BSP crossplan 95,0<br />

Gypsum fi breboard (12,5 mm) 12,5<br />

Overall<br />

thickness mm<br />

Fire protection Sound<br />

insulation<br />

258 REI 90*<br />

Airborne noise<br />

R W 42 dB<br />

Exterior wall / with timber façade / not ventilated / with service layer<br />

Exterior wall / with plaster façade / not ventilated / with service layer<br />

Wall cross-section from<br />

outside to inside<br />

Thickness<br />

mm<br />

Plaster 4,0<br />

Rockwool MW-PT<br />

120,0<br />

Plaster-base sheeting<br />

M1 BSP crossplan 98,0<br />

Timber spruce battens (40 / 50)<br />

on bracket<br />

70,0<br />

Glasswool [0,040; R = 16]<br />

d = 50 mm<br />

Gypsum fi breboard (2 × 12,5 mm)<br />

or Gypsum fi breboard (2 × 10 mm)<br />

25,0<br />

Overall<br />

thickness mm<br />

Fire protection Sound<br />

insulation<br />

317 REI 120*<br />

Airborne<br />

noise<br />

R W 53 DB<br />

Thermal<br />

insulation<br />

U value<br />

0,35 [W / m 2 K]<br />

Wall cross-section from<br />

Thickness Overall Fire protection Sound Thermal<br />

outside to inside<br />

mm thickness mm<br />

insulation insulation<br />

Exterior wall cladding 20,0<br />

339 REI 90*<br />

Airborne<br />

noise<br />

RW 51 DB<br />

U value<br />

0,19 [W / m2 Timber spruce battens (30 / 60) 30,0<br />

Vapour-permeable membrane Sd ≤ 0,3 M –<br />

Timber spruce battens (50 / 60)<br />

Rockwool [0,040; R ≥ 70]<br />

50,0<br />

Timber battens spruce (80 / 60)<br />

Rockwool [0,040; R ≥ 70]<br />

M1 BSP crossplan<br />

Timber spruce battens (40 / 50)<br />

80,0<br />

98,0<br />

K]<br />

on bracket<br />

Rockwool [0,040; R ≥ 28] d = 50<br />

50,0<br />

Gypsum fi breboard (12,5 mm) or<br />

Gypsum fi breboard (10 mm)<br />

12,5<br />

Thermal<br />

insulation<br />

U value<br />

0,20 [W / m 2 K]<br />

Exterior wall / with plaster façade / not ventilated / without service layer<br />

Wall cross-section from<br />

outside to inside<br />

Thickness<br />

mm<br />

Plaster 4,0<br />

Rockwool MW-PT<br />

Plaster-base sheeting<br />

120,0<br />

M1 BSP crossplan 95,0<br />

Overall<br />

thickness mm<br />

* according classifi cation reports M1 BSP crossplan of HFA<br />

Fire protection Sound<br />

insulation<br />

219 REI 60*<br />

Airborne noise<br />

R W 38 DB<br />

Source: www.dataholz.com, catalogue «Bauphysikalisch geprüfter Bauteile für den Holzbau»<br />

Thermal<br />

insulation<br />

U value<br />

0,26 [W / m 2 K]<br />