CONSTRUCTION DETAILS<br />

WALL CONSTRUCTION<br />

Partition wall / without service layer<br />

Wall cross-section from<br />

left to right<br />

Partition wall / without service layer<br />

Partition wall / with service layer<br />

Wall cross-section from<br />

left to right<br />

Partition wall / with service layer<br />

Version 1 / 2011<br />

Thickness<br />

mm<br />

Gypsum fi breboard 12,5 mm 12,5<br />

M1 BSP crossplan 95,0<br />

Impact noise insulation panel MW-T 30,0<br />

M1 BSP crossplan<br />

Timber spruce battens (40 / 50)<br />

95,0<br />

on bracket<br />

Glass wool [0,040; R = 16]<br />

d = 50 mm<br />

50,0<br />

Gypsum fi breboard 12,5 mm 12,5<br />

Wall cross-section from<br />

left to right<br />

Thickness<br />

mm<br />

M1 BSP crossplan 95,0<br />

Impact noise insulation panel<br />

MW-T<br />

30,0<br />

M1 BSP crossplan 95,0<br />

Wall cross-section from<br />

left to right<br />

Thickness<br />

mm<br />

Gypsum fi breboard 12,5 mm 12,5<br />

M1 BSP crossplan 95,0<br />

Impact noise insulation panel MW-T 30,0<br />

M1 BSP crossplan 95,0<br />

Gypsum fi breboard 12,5 mm<br />

Construction without gypsum<br />

fi breboards<br />

12,5<br />

Thickness<br />

mm<br />

Gypsum fi breboard 12,5 mm 12,5<br />

Rockwool [0,04I; R = 27] d = 60 mm<br />

Timber spruce battens (40/50) 70,0<br />

on bracket<br />

M1 BSP crossplan 98,0<br />

Timber spruce battens (40/50)<br />

on bracket<br />

70,0<br />

Rockwool [0,04I; R = 27] d = 60 mm<br />

Gypsum fi breboard 12,5 mm 12,5<br />

Overall<br />

thickness mm<br />

220 REI 60*<br />

Overall<br />

thickness mm<br />

245<br />

Overall<br />

thickness mm<br />

Fire protection Sound<br />

insulation<br />

295 REI 90*<br />

Overall<br />

thickness mm<br />

* according classifi cation reports M1 BSP crossplan of HFA<br />

Fire protection Sound<br />

insulation<br />

Fire protection<br />

263 REI 90*<br />

Airborne noise<br />

R W 48 dB<br />

Fire protection Sound<br />

insulation<br />

REI 90*<br />

Airborne noise<br />

R W 56 dB<br />

Airborne noise<br />

R W 62 DB<br />

Sound<br />

insulation<br />

Airborne noise<br />

R W 58 DB<br />

M1 BSP crossplan<br />

Thermal<br />

insulation<br />

U value<br />

0,39<br />

[W / m 2 K]<br />

Thermal<br />

insulation<br />

U value<br />

0,38 [W / m 2 K]<br />

220 48 dB 0,39 [W / m 2 K]<br />

Source: www.dataholz.com, catalogue «Bauphysikalisch geprüfter Bauteile für den Holzbau»<br />

Thermal<br />

insulation<br />

U value<br />

0,27 [W / m2K] Thermal<br />

insulation<br />

U value<br />

0,25 [W / m 2 K]<br />

WTW 01<br />

inside inside<br />

WTW 02<br />

inside inside<br />

WTW 03<br />

inside inside<br />

WTW 04<br />

inside inside<br />

Mayr-Melnhof Kaufmann 27