1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

<strong>Operating</strong> <strong>Manual</strong> EAV 24<br />

Figure 3.4-1: Terminal assignment of the transponder reader<br />

to/from the motor housing<br />

or cable transition<br />

e. g. Connector<br />

block (via electrical<br />

contractor)<br />

white<br />

brown<br />

green<br />

yellow<br />

grey<br />

cable of 2 x 0.8 mm²,<br />

length of max. 40 m<br />

[43.744 yd]<br />

(plus) (minus)<br />

power supply<br />

12V DC/2A<br />

L<br />

N PE<br />

Figure 3.4-2: Installation of the transponder reader<br />

230V/50Hz<br />

No. Terminals<br />

1 „12V DC“<br />

2 „0V DC“<br />

3 serial interface<br />

4 serial interface<br />

5 antenna<br />

6 antenna<br />

7 potential free contact C<br />

8 potential free contact NO<br />

antenna<br />

„Open“<br />

button<br />

Recommendation:<br />

flush-type box or junction<br />

box for cable connection<br />

Aug. <strong>Winkhaus</strong> GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen · www.winkhaus.de<br />

Subject to technical changes<br />

Print-no. 250 020 1<br />

08/2009<br />

cable of 2 x 0.8 mm², length of max. 100 m<br />

[109.36 yd] (up to the last open button/up<br />

to the last access control system)<br />

automatic<br />

door opener<br />

(optional)<br />

antenna cable readymade,<br />

2.5 m [2.734 yd]<br />

fixed at the antenna,<br />

cable terminals with<br />

wire and bushes<br />

length and cross section: specification by<br />

the manufacturer of automatic door opener