No. Name Default Min Max Unit <strong>Description</strong><br />

.1.3. • supply voltage 0 0 40,96 V S<strong>en</strong>sor operating voltage display<br />

.1.4. • temperature 0 -40 100 °C PCB temperature in °C<br />

<strong>Color</strong> <strong>line</strong> s<strong>en</strong>sor <strong>FE</strong> <strong>5002</strong><br />

.1.5. • sharpness 0 0 16 - Optical sharpness of the guiding criterion<br />

Note: a high value in this parameter is more important<br />

than a high value in parameter .1.6.<br />

.1.6. • perc<strong>en</strong>t of valid 0 0 100 % Guiding criterion detected to X per c<strong>en</strong>t<br />

The frequ<strong>en</strong>cy of how oft<strong>en</strong> the guiding criterion was<br />

detected is indicated in per c<strong>en</strong>t.<br />

Note: 70 % for a brok<strong>en</strong> guiding criterion is a good value.<br />

.1.7. • dsp scan status 0 0 5 - Status feedback from DSP(for service personnel only)<br />

.1.8. • dsp reason of lost 0 0 10 - Reason for lost guiding criterion<br />

0 = no guiding criterion in s<strong>en</strong>sor scanning range<br />

1 = only one edge of a <strong>line</strong> detected<br />

2 = fluctuating signal, no guiding criterion may be clearly<br />

detected<br />

3 = Line tolerance exceeded<br />

4 = Brightness tolerance exceeded<br />

5 = Tolerance for standardised contrast exceeded<br />

6 = Colour tolerance red/gre<strong>en</strong>, one <strong>line</strong> or left of<br />

contrasting edge exceeded<br />

7 = Colour tolerance blue/gree, one <strong>line</strong> or left of<br />

contrasting edge exceeded<br />

8 = Colour tolerance red/gre<strong>en</strong>, right of contrasting<br />

edge exceeded<br />

9 = Colour tolerance blue/gre<strong>en</strong>, right of contrasting<br />

edge exceeded<br />

10 = Guiding criterion detected<br />

.1.9. working parameters - - - - Parameter title<br />

.2.0. > teaching mode 0 0 3 - Selection of teaching mode<br />

0 = automatic teaching<br />

1 = manual teaching<br />

2 = combined teaching (manual and automatic)<br />

3 = no teaching possible the best guiding criterion<br />

detected in the measuring range is adopted as the<br />

guiding criterion<br />

.2.1. <strong>en</strong>ergetic IIR-tau 0,22 0,05 2,00 mm IIR time constant<br />

Narrow <strong>line</strong>s are damp<strong>en</strong>ed.<br />

Note: this parameter is only active if value 3<br />

is selected in parameter .2.0..<br />

.2.2. <strong>en</strong>ergetic mov 2,00 0,05 5,00 mm Evaluation width<br />

AV width Wide <strong>line</strong>s are damp<strong>en</strong>ed<br />

Note: This parameter is only active if value 3 is selected in<br />

parameter .2.0..<br />

.2.3. <strong>line</strong> width minimum 0,12 0,12 7,00 mm Minimum <strong>line</strong> width during teaching<br />

Line thickness less than this value will not be accepted.<br />

.2.4. <strong>line</strong> width maximum 8,00 0,50 12,00 mm Maximum <strong>line</strong> width during teaching<br />

Line width greater than this value will not be accepted.<br />

.2.5. • <strong>line</strong> width actual - 0,00 8,00 mm Display of <strong>line</strong> width (during contrasting edge scanning<br />

display 0.00 is indicated)<br />