<strong>CFHT</strong> Observatory Manual - Observatory (Sec.4) http://www.cfht.hawaii.edu/Instruments/ObservatoryManual/CFH...<br />

D.C. supplies.<br />

The following A.C. power is available at Cass.<br />

220 V.A.C. 50 HZ power is available in standard French sockets<br />

800 watts maximum.<br />

208 V.A.C. 60 HZ 3 phase power is available in standard French sockets<br />

2000 watts maximum.<br />

208 V.A.C. 60 HZ 3 phase power is available in standard American sockets<br />

3000 watts maximum.<br />

110 V.A.C. 60 HZ power is available in several places at Cass.<br />

Instrumentation Cabling<br />

The general purpose instrumentation cabling available at the Cassegrain<br />

focus consists of various sizes of overall shielded twisted pair,<br />

individually shielded twisted pair and coax cables. These connectors run<br />

between the CFP2A (Cassegrain Focus Panel 2A) at the Cassegrain<br />

environment and the CPP2 in the observers room on the fourth floor.<br />

Cryogen Pumping System<br />

A vacuum system is available for pumping on cryogens, as is required with some IR<br />

detectors. There are two separate<br />

lines each connected to a Sargeant-Welch Model 1397 mechanical pump (500 liters/minute)<br />

located on the second floor.<br />

The lines terminate at a manifold which is permanently installed on the Cassegrain<br />

environment. The manifold has valves<br />

which permit the two systems to be used independently or in parallel and vacuum gauges to<br />

monitor the pressure. The<br />

connection between the manifold and the cryostat is made with flexible plastic tubing and<br />

Klamp Flange or Alcatel KF<br />

10 or 16 fittings.<br />

Observers needing this facility must so specify on the Visitor Instrument Questionnaire and<br />

on the Guest Observer<br />

Information Sheet. Note that use of the system severely restricts the range of rotation of the<br />

Cassegrain environment.<br />

If this is a potential problem, it should be discussed with <strong>CFHT</strong> staff well in advance of the<br />