D.C. supplies.<br />
The following A.C. power is available at Cass.<br />
220 V.A.C. 50 HZ power is available in standard French sockets<br />
800 watts maximum.<br />
208 V.A.C. 60 HZ 3 phase power is available in standard French sockets<br />
2000 watts maximum.<br />
208 V.A.C. 60 HZ 3 phase power is available in standard American sockets<br />
3000 watts maximum.<br />
110 V.A.C. 60 HZ power is available in several places at Cass.<br />
Instrumentation Cabling<br />
The general purpose instrumentation cabling available at the Cassegrain<br />
focus consists of various sizes of overall shielded twisted pair,<br />
individually shielded twisted pair and coax cables. These connectors run<br />
between the CFP2A (Cassegrain Focus Panel 2A) at the Cassegrain<br />
environment and the CPP2 in the observers room on the fourth floor.<br />
Cryogen Pumping System<br />
A vacuum system is available for pumping on cryogens, as is required with some IR<br />
detectors. There are two separate<br />
lines each connected to a Sargeant-Welch Model 1397 mechanical pump (500 liters/minute)<br />
located on the second floor.<br />
The lines terminate at a manifold which is permanently installed on the Cassegrain<br />
environment. The manifold has valves<br />
which permit the two systems to be used independently or in parallel and vacuum gauges to<br />
monitor the pressure. The<br />
connection between the manifold and the cryostat is made with flexible plastic tubing and<br />
Klamp Flange or Alcatel KF<br />
10 or 16 fittings.<br />
Observers needing this facility must so specify on the Visitor Instrument Questionnaire and<br />
on the Guest Observer<br />
Information Sheet. Note that use of the system severely restricts the range of rotation of the<br />
Cassegrain environment.<br />
If this is a potential problem, it should be discussed with <strong>CFHT</strong> staff well in advance of the<br />
run.<br />
Cassegrain Bonnette<br />
Overview<br />