Ice ‘N Water Systems<br />

Table A: Harness 10-pin Connector Configuration<br />

Pin Color Signal<br />

1 GY Ice Door Chute Solenoid<br />

2 BR Dispenser Light<br />

3 BU Crushed<br />

4 OR Cubed<br />

5 BK Line Out<br />

6 RD Main Actuator<br />

7 YL Water Valve<br />

8 VT Line In<br />

9<br />

10 WH Neutral<br />

Note: All voltage measurements are referenced to line neutral or pin 10 (WH wire) of 10-pin connector.<br />

Symptom Possible Cause Test Procedure Repair<br />

No LED lit<br />

Switch failure in With unit powered, open freezer door. Press freezer door Replace<br />

freezer door.<br />

switch in. If freezer light does not turn off, switch is defective. switch.<br />

Incorrect harness Verify wire color on 10-pin connector. Refer to Table A. Correct<br />

wiring.<br />

wiring.<br />

No power to the PCB. With unit powered, measure voltage between (WH wire) and Replace PCB<br />

(VT wire) pin 8 of 10-pin connector. Meter should read<br />

if meter reads<br />

120VAC.<br />

120VAC.<br />

No dispenser light No continuity.<br />

Disconnect power. Measure continuity between (BR wire) pin Repair open<br />

when Main or<br />

Water dispenser<br />

2 of 10-pin connector and dispenser lamp terminal.<br />

connection.<br />

switch is pressed Failed light bulb or With unit powered, press the Main dispenser switch.<br />

Replace<br />

in Water, Crushed PCB.<br />

Measure voltage on pin 2 (BR wire) of 10-pin connector. dispenser<br />

or Cubed mode.<br />

Voltage should read 120 VAC.<br />

light bulb if<br />

voltage reads<br />

120 VAC.<br />

Dispenser light is Failed Main dispenser Disconnect power. Remove both leads from the switch and Replace<br />

on without<br />

switch (failed short) measure resistance across switch terminals. Resistance switch<br />

pressing the Main<br />

should read less than 1 Ω in this position and higher than 10<br />

or Water dispenser<br />

MΩ when switch is open.<br />

switch in Water,<br />

Crushed or Cubed<br />

mode.<br />

Failed PCB<br />

With PCB powered, measure voltage on pin 3 (BU wire) of 10pin<br />

connector. Voltage should read 0 VAC.<br />

Replace PCB.<br />

Water LED is Failed Main dispenser Disconnect power. Remove both leads from the switch and Replace<br />

illuminated but switch (failed open) measure resistance across switch terminals. Resistance switch.<br />

does not dispense<br />

should read less than 1 Ω in this position and higher than 10<br />

water when Main<br />

MΩ when switch is open.<br />

dispenser switch is<br />

pressed.<br />

No continuity<br />

Disconnect power. Remove the cover of freezer door hinge<br />

located on top of the unit and disconnect the connectors.<br />

Check OR wire (pin 4 of 10-pin connector) for continuity.<br />

Repair open<br />

connection.<br />

Water starts to Failed Main dispenser Disconnect power. Remove both leads from the switch and Replace<br />

dispense as soon switch (failed short) measure resistance across switch terminals. Resistance switch.<br />

as Water mode is<br />

should read less than 1 Ω in this position and higher than 10<br />

selected without<br />

MΩ when switch is open.<br />

pressing the Main<br />

dispenser switch<br />

Failed PCB<br />

With PCB powered, measure voltage on pin 7 (YL wire) of 10pin<br />

connector. Voltage should read 0 VAC.<br />

Replace PCB.<br />