Ice ‘N Water Systems<br />
Symptom Possible<br />
Cause<br />
Crushed LED is illuminated Failed Main<br />
but does not dispense dispenser<br />
crushed ice when Main switch (failed<br />
dispenser switch is<br />
pressed.<br />
open)<br />
No continuity<br />
Crushed ice starts to<br />
dispense as soon as<br />
Crushed mode is selected<br />
without pressing the Main<br />
dispenser switch.<br />
Failed auger<br />
motor or PCB.<br />
Failed Main<br />
dispenser<br />
switch (failed<br />
short)<br />
Failed PCB<br />
Seconds to dispense 10 oz. water<br />
Supply pressure 35 psig 45 psig 55 psig 75 psig<br />
Filter model<br />
Bypass installed<br />
Filter model<br />
New filter installed<br />
Test Procedure Repair<br />
Disconnect power. Remove both leads from the<br />
switch and measure resistance across switch<br />
terminals. Resistance should read less than 1 Ω in<br />
this position and higher than 10 MΩ when switch<br />
is open.<br />
Disconnect power. Remove the cover of freezer<br />
door hinge located on top of the unit and<br />
disconnect the connectors. Check BU wire (pin 3<br />
of 10-pin connector) for continuity.<br />
With PCB powered, press the Main dispenser<br />
switch. Measure voltage on pin 3 (BU wire) of 10-<br />
pin connector. Voltage should read 120VAC.<br />
Disconnect power. Remove both leads from the<br />
switch and measure resistance across switch<br />
terminals. Resistance should read less than 1 Ω in<br />
this position and higher than 10 MΩ when switch<br />
is open.<br />
With PCB powered, measure voltage on pin 3 (BU<br />
wire) of 10-pin connector. Voltage should read 0<br />
VAC.<br />
9.0 8.0 7.0 6.0<br />
11.0 10.0 8.0 7.0<br />
Replace switch.<br />
Repair open<br />
connection.<br />
Replace auger motor if<br />
voltage reads 120VAC.<br />
If not, replace PCB.<br />
Replace switch<br />
Replace PCB.<br />
<strong>Amana</strong> specifies a minimum supply pressure of 35 psig for water filter units. Minimum pressure<br />
requirement ensures that water valves close and sufficient water volume is available to fill icemaker.<br />
Proper fill is 140 cc. of water in 7.5 seconds. Failure of water valves to close because of low pressure<br />
will result in fill-tube freeze-up or dripping at cavity.<br />
©2005 Maytag <strong>Service</strong>s 16025628 39