Ice ‘N Water Systems<br />

Symptom Possible<br />

Cause<br />

Crushed LED is illuminated Failed Main<br />

but does not dispense dispenser<br />

crushed ice when Main switch (failed<br />

dispenser switch is<br />

pressed.<br />

open)<br />

No continuity<br />

Crushed ice starts to<br />

dispense as soon as<br />

Crushed mode is selected<br />

without pressing the Main<br />

dispenser switch.<br />

Failed auger<br />

motor or PCB.<br />

Failed Main<br />

dispenser<br />

switch (failed<br />

short)<br />

Failed PCB<br />

Seconds to dispense 10 oz. water<br />

Supply pressure 35 psig 45 psig 55 psig 75 psig<br />

Filter model<br />

Bypass installed<br />

Filter model<br />

New filter installed<br />

Test Procedure Repair<br />

Disconnect power. Remove both leads from the<br />

switch and measure resistance across switch<br />

terminals. Resistance should read less than 1 Ω in<br />

this position and higher than 10 MΩ when switch<br />

is open.<br />

Disconnect power. Remove the cover of freezer<br />

door hinge located on top of the unit and<br />

disconnect the connectors. Check BU wire (pin 3<br />

of 10-pin connector) for continuity.<br />

With PCB powered, press the Main dispenser<br />

switch. Measure voltage on pin 3 (BU wire) of 10-<br />

pin connector. Voltage should read 120VAC.<br />

Disconnect power. Remove both leads from the<br />

switch and measure resistance across switch<br />

terminals. Resistance should read less than 1 Ω in<br />

this position and higher than 10 MΩ when switch<br />

is open.<br />

With PCB powered, measure voltage on pin 3 (BU<br />

wire) of 10-pin connector. Voltage should read 0<br />

VAC.<br />

9.0 8.0 7.0 6.0<br />

11.0 10.0 8.0 7.0<br />

Replace switch.<br />

Repair open<br />

connection.<br />

Replace auger motor if<br />

voltage reads 120VAC.<br />

If not, replace PCB.<br />

Replace switch<br />

Replace PCB.<br />

<strong>Amana</strong> specifies a minimum supply pressure of 35 psig for water filter units. Minimum pressure<br />

requirement ensures that water valves close and sufficient water volume is available to fill icemaker.<br />

Proper fill is 140 cc. of water in 7.5 seconds. Failure of water valves to close because of low pressure<br />

will result in fill-tube freeze-up or dripping at cavity.<br />

©2005 Maytag <strong>Service</strong>s 16025628 39