Configuring the Switching Mechanism<br />

GPI Input Control<br />

Chapter 3: Configuration <strong>and</strong> <strong>Operation</strong><br />

Three factors control the output channels on the <strong>ACO6800+</strong>:<br />

• GPI control<br />

• Alarm severity levels for each input channel<br />

• Parameters that can be manually switched in CCS Navigator or at the card<br />

edge<br />

Use the following parameters in the Switch Settings group of parameters to<br />

define the switch priority levels:<br />

• Group A or Group B Switch High Priority (the default setting is GPI Input)<br />

• Group A or Group B Switch Medium Priority (the default setting is <strong>Manual</strong>)<br />

• Group A or Group B Switch Low Priority (the default setting is Alarms)<br />

A high priority event overrides a medium priority event, which overrides a low<br />

priority event. The three options are mutually exclusive.<br />

As an example, the current settings might start out in these default values:<br />

• Group A Switch High Priority: GPI Input<br />

• Group A Switch Medium Priority: <strong>Manual</strong><br />

• Group A Switch Low Priority: Alarms<br />

By changing the Group A Switch Low Priority setting to GPI Input, the module<br />

automatically changes the Group A Switch High Priority setting to Alarms. This<br />

new setting is exclusive, <strong>and</strong> will not conflict with the Medium <strong>and</strong> Low settings.<br />

Table 3-3 indicates what happens when a GPI Input is activated—for example,<br />

pressing a button on a panel—when the switching is not triggered by other higher<br />

priority events than GPI Input.<br />

Table 3-3. GPI Input Control<br />

GPI Action/Result<br />

GPI 1 Switches output source to IN 1<br />

GPI 2 Switches output source to IN 2<br />

<strong>ACO6800+</strong> <strong>Installation</strong> <strong>and</strong> <strong>Operation</strong> <strong>Manual</strong> 25<br />

Copyright © 2009, Harris Corporation