Failure of Auto/<strong>Manual</strong> switchover<br />

Sample Scenario One<br />

Chapter 3: Configuration <strong>and</strong> <strong>Operation</strong><br />

If your auto/manual switchover does not work as expected, confirm that the<br />

following parameters have been configured correctly:<br />

• Group (A/B) GPI Input_(1-3) should confirm the GPI Input condition.<br />

• Group A or Group B <strong>Manual</strong> Switch should confirm the expected setting.<br />

• Group A or Group B Switch (High/Medium/Low) Priority should display<br />

the sort of logic seen in Table 3-6 <strong>and</strong> Table 3-8.<br />

• Group A or Group B Alarm Switch Level should confirm the triggered<br />

level.<br />

Confirm that the configurable portions of sub-device alarms match your<br />

expectations. (This includes Enable/Disable, Alarm Priority, Trigger Time, <strong>and</strong><br />

Clear Time.)<br />

For <strong>ACO6800+</strong>ISCST modules, ensure that the Video St<strong>and</strong>ard <strong>and</strong> <strong>Operation</strong><br />

St<strong>and</strong>ard parameters have the same setting. The Still Image Mode parameter<br />

must be set to Auto, <strong>and</strong> the Force Freeze <strong>and</strong> Force Black parameters must be<br />

set to Off.<br />

The initial settings for sample scenario one are outlined in Table 3-5.<br />

Table 3-5. Sample Scenario One: Parameter Settings<br />

Parameter Setting<br />

Group A Switch High Priority GPI Input<br />

Group A Switch Medium Priority <strong>Manual</strong><br />

Group A Switch Low Priority Alarms<br />

Group A Alarm Switch Level 6<br />

Group A <strong>Manual</strong> Switch Disable<br />

A1 SDI Loss of Video: Priority 6<br />

A1 SDI Loss of Video: Trigger 2 s<br />

A1 SDI Loss of Video: Clear 10 s<br />

<strong>ACO6800+</strong> <strong>Installation</strong> <strong>and</strong> <strong>Operation</strong> <strong>Manual</strong> 27<br />