E.6. Estimation <strong>of</strong> Emission reductions <strong>of</strong> a CPA:<br />
E.6.1. Explanation <strong>of</strong> methodological choices,<br />
provided in the approved baseline and monitoring<br />
methodology applied, selected for a typical SSC-<br />
CPA:<br />
>> The applied AMS IIC version 10, provides<br />
methodological choices to be made. The SSC-CPA shall<br />
indicate the choices in the following manner:<br />
For each replaced appliance/equipment the capacity<br />
or output or level <strong>of</strong> service (e.g., light output, room<br />
temperature and comfort, the rated output capacity<br />
<strong>of</strong> air-conditioners etc.) is not significantly larger or<br />
smaller (maximum ± 10%) than the baseline.<br />
The distributed <strong>CFL</strong> lamps under the CPA shall meet<br />
the applicable Indian Standard IS: 15111 for <strong>CFL</strong>s<br />
including amendments on date.<br />
The output capacity (rated luminous flux in lumens)<br />
<strong>of</strong> the distributed <strong>CFL</strong> shall be within ± 10% <strong>of</strong> the<br />
baseline ICL lamp replaced as follows:<br />
Baseline ICL Rated Lumen Matching <strong>CFL</strong><br />
replaced (Watt) output under SSC-CPA<br />
(Watt)<br />
40 W 440 9-10 W<br />
60 W 720 13-15 W<br />
75 W 900 16-17W<br />
100 W 1200 20-23W<br />
If the devices installed have a constant current<br />
(ampere) characteristics, monitoring shall consist <strong>of</strong><br />
monitoring either the "power" and "operating hours"<br />
or the "energy use" <strong>of</strong> the devices installed using an<br />
appropriate method. Appropriate methods include:<br />
(a) Recording the "power" <strong>of</strong> the device installed<br />
(e.g., lamp or refrigerator) using nameplate data<br />
or bench tests <strong>of</strong> a sample <strong>of</strong> the units installed<br />
and metering a sample <strong>of</strong> the units installed for<br />
their operating hours using run time meters;<br />
OR<br />
(b) Metering the "energy use" <strong>of</strong> an appropriate<br />
sample <strong>of</strong> the devices installed.<br />
32 Bureau <strong>of</strong> Energy Efficiency<br />
<strong>CFL</strong>s have constant current (ampere) characteristics,<br />
and hence as per AMS IIC, SSC-CPA shall indicate<br />
monitoring choice as either:<br />
Monitoring SSC-CPA Option<br />
(check on box)<br />
1. "power": p i is the rated<br />
Wattage <strong>of</strong> the installed<br />
<strong>CFL</strong> using nameplate<br />
data or bench tests <strong>of</strong><br />
a sample <strong>of</strong> the <strong>CFL</strong>s<br />
installed.<br />
2. "operating hours" : o i is<br />
the <strong>CFL</strong> use by metering<br />
a sample <strong>of</strong> the <strong>CFL</strong>s<br />
installed using run-time<br />
meters<br />
OR<br />
3. "energy use": Metering<br />
the "energy use" <strong>of</strong> an<br />
appropriate sample <strong>of</strong><br />
the <strong>CFL</strong>s installed.<br />
E.6.2. Equations, including fixed parametric values,<br />
to be used for calculation <strong>of</strong> emission reductions <strong>of</strong><br />
a SSC-CPA:<br />
>> The emission reduction achieved by the SSC-CPA<br />
project activity shall be determined as the difference<br />
between the baseline emissions and the project<br />
emissions and leakage.<br />
ER = ((BE – PE ) * BP) – LE y y y y<br />
Where:<br />
ER y : Emission reductions in year y (tCO 2 e)<br />
BE y : Baseline emissions in year y (tCO 2 e)<br />
PE y : Project emissions in year y (tCO 2 e)<br />
LE y : Leakage emissions in year y (tCO 2 e)<br />
BP: Baseline penetration factor<br />
Baseline emissions<br />
In the context <strong>of</strong> the SSC-CPA, the baseline lamp (ICL)<br />
electricity consumption can be derived by its rated<br />
power.<br />
BE = E * EF (2)<br />
y BL,y CO2,ELEC,y<br />
(1)