E.6. Estimation <strong>of</strong> Emission reductions <strong>of</strong> a CPA:<br />

E.6.1. Explanation <strong>of</strong> methodological choices,<br />

provided in the approved baseline and monitoring<br />

methodology applied, selected for a typical SSC-<br />

CPA:<br />

>> The applied AMS IIC version 10, provides<br />

methodological choices to be made. The SSC-CPA shall<br />

indicate the choices in the following manner:<br />

For each replaced appliance/equipment the capacity<br />

or output or level <strong>of</strong> service (e.g., light output, room<br />

temperature and comfort, the rated output capacity<br />

<strong>of</strong> air-conditioners etc.) is not significantly larger or<br />

smaller (maximum ± 10%) than the baseline.<br />

The distributed <strong>CFL</strong> lamps under the CPA shall meet<br />

the applicable Indian Standard IS: 15111 for <strong>CFL</strong>s<br />

including amendments on date.<br />

The output capacity (rated luminous flux in lumens)<br />

<strong>of</strong> the distributed <strong>CFL</strong> shall be within ± 10% <strong>of</strong> the<br />

baseline ICL lamp replaced as follows:<br />

Baseline ICL Rated Lumen Matching <strong>CFL</strong><br />

replaced (Watt) output under SSC-CPA<br />

(Watt)<br />

40 W 440 9-10 W<br />

60 W 720 13-15 W<br />

75 W 900 16-17W<br />

100 W 1200 20-23W<br />

If the devices installed have a constant current<br />

(ampere) characteristics, monitoring shall consist <strong>of</strong><br />

monitoring either the "power" and "operating hours"<br />

or the "energy use" <strong>of</strong> the devices installed using an<br />

appropriate method. Appropriate methods include:<br />

(a) Recording the "power" <strong>of</strong> the device installed<br />

(e.g., lamp or refrigerator) using nameplate data<br />

or bench tests <strong>of</strong> a sample <strong>of</strong> the units installed<br />

and metering a sample <strong>of</strong> the units installed for<br />

their operating hours using run time meters;<br />

OR<br />

(b) Metering the "energy use" <strong>of</strong> an appropriate<br />

sample <strong>of</strong> the devices installed.<br />

32 Bureau <strong>of</strong> Energy Efficiency<br />

<strong>CFL</strong>s have constant current (ampere) characteristics,<br />

and hence as per AMS IIC, SSC-CPA shall indicate<br />

monitoring choice as either:<br />

Monitoring SSC-CPA Option<br />

(check on box)<br />

1. "power": p i is the rated<br />

Wattage <strong>of</strong> the installed<br />

<strong>CFL</strong> using nameplate<br />

data or bench tests <strong>of</strong><br />

a sample <strong>of</strong> the <strong>CFL</strong>s<br />

installed.<br />

2. "operating hours" : o i is<br />

the <strong>CFL</strong> use by metering<br />

a sample <strong>of</strong> the <strong>CFL</strong>s<br />

installed using run-time<br />

meters<br />

OR<br />

3. "energy use": Metering<br />

the "energy use" <strong>of</strong> an<br />

appropriate sample <strong>of</strong><br />

the <strong>CFL</strong>s installed.<br />

E.6.2. Equations, including fixed parametric values,<br />

to be used for calculation <strong>of</strong> emission reductions <strong>of</strong><br />

a SSC-CPA:<br />

>> The emission reduction achieved by the SSC-CPA<br />

project activity shall be determined as the difference<br />

between the baseline emissions and the project<br />

emissions and leakage.<br />

ER = ((BE – PE ) * BP) – LE y y y y<br />

Where:<br />

ER y : Emission reductions in year y (tCO 2 e)<br />

BE y : Baseline emissions in year y (tCO 2 e)<br />

PE y : Project emissions in year y (tCO 2 e)<br />

LE y : Leakage emissions in year y (tCO 2 e)<br />

BP: Baseline penetration factor<br />

Baseline emissions<br />

In the context <strong>of</strong> the SSC-CPA, the baseline lamp (ICL)<br />

electricity consumption can be derived by its rated<br />

power.<br />

BE = E * EF (2)<br />

y BL,y CO2,ELEC,y<br />

(1)