Justification <strong>of</strong> the The SSC-CPA owner supported by DISCOM (i) will monitor pi,<strong>CFL</strong> during<br />

choice <strong>of</strong> data or the each <strong>CFL</strong> use monitoring period. The data will be entered into the SSCdescription<br />

<strong>of</strong> CPA database.<br />

measurement methods In the case <strong>of</strong> both retr<strong>of</strong>it and new installations, "power" is the weighted<br />

and procedures average <strong>of</strong> the <strong>CFL</strong>s installed.<br />

actually applied :<br />

QA/QC procedures Use <strong>of</strong> standardized data forms and compliance protocols <strong>of</strong> DISCOM/ SSC-CPA.<br />

to be applied:<br />

Any comment: Data to be reported to BEE for review<br />

Data / Parameter: EF CO2,ELEC,y<br />

Data unit: tCO 2 /kWh<br />

Description: CO 2 emission factor for displacement <strong>of</strong> electricity in the grid serving<br />

the household consumers that participate in the SSC-CPA during the<br />

monitoring interval y, calculated according to the latest approved version <strong>of</strong><br />

AMS-I.D (tCO 2 /kWh)<br />

Source <strong>of</strong> data used: The latest version <strong>of</strong> <strong>CDM</strong> baseline CO 2 emission database by Central<br />

Electricity Authority (CEA), India<br />

Value applied: SSC-CPA to apply as per the grid-connectivity<br />

Justification <strong>of</strong> the The SSC-CPA owner shall apply the latest grid emission factor database<br />

choice <strong>of</strong> data or available on the CEA website.<br />

description <strong>of</strong><br />

measurement methods<br />

and procedures<br />

actually applied :<br />

QA/QC procedures N/A<br />

to be applied:<br />

Any comment: Data to be reported to BEE for review<br />

E.7.2. Description <strong>of</strong> the monitoring plan for a SSC-<br />

CPA:<br />

>>The Monitoring for the SSC-CPA would be carried<br />

out at the following levels:<br />

1. Baseline Penetration Survey<br />

2. Continuous <strong>CFL</strong> Use Monitoring<br />

3. Cross-check group monitoring<br />

4. ICL/ fused <strong>CFL</strong> Scrapping survey<br />

5. Roles and Responsibilities<br />

6. Training and Calibration<br />

40 Bureau <strong>of</strong> Energy Efficiency<br />

The description <strong>of</strong> each <strong>of</strong> the levels is provided in the<br />

following pages.<br />

1. Baseline Penetration Survey<br />

Random Selection <strong>of</strong> households<br />

For any proposed SSC-CPA area, the responsible<br />

DISCOM, will generate a database listing all<br />

residential households eligible under the SSC-CPA.<br />

From this set <strong>of</strong> customers a sample household pool<br />

will be randomly selected for the baseline survey. to<br />

form the Baseline Sample Group (BSG). The BSG<br />

would be set as per following criteria: