1.4 Checking the Burner Manifold Gas Pressure<br />

1. On non-CE fryers, ensure that the gas valve knob is in the OFF position.<br />

Honeywell<br />

2. Remove the pressure tap plug from the gas valve assembly.<br />

Typical Non-CE<br />

Valve Assembly<br />

OFF<br />

Pressure Tap Plug<br />

1-6<br />

ON<br />

Typical CE Valve<br />

Assembly<br />

2. Insert the fitting for a gas pressure-measuring device into the pressure tap hole.<br />

3. On non-CE fryers only, place the gas valve in the ON position.<br />

4. Place the fryer power switch in the ON position. When the burner has lit and burned steadily for<br />

at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in<br />

the appropriate table found on the following page. The tables list the burner manifold gas<br />

pressures for each of the gas types that can be used with this equipment.