2.7 Component Box Assemblies and Associated Component Parts<br />
IFB 806-3398 (Discontinued) has only one<br />
fuse. If used with 807-3365 or 807-3366<br />
modules, an in-line fuse should be added<br />
between the module and the board.<br />
Replaced by 106-0386<br />
1<br />
2<br />
9<br />
10<br />
8<br />
12<br />
11<br />
5<br />
13<br />
15<br />
14<br />
6<br />
7<br />
2-20<br />
16<br />
IFB 106-0386 (Item 7) has two<br />
fuses and may be used with any<br />
of the ignition modules.<br />
6<br />
17<br />
2<br />
Full vat units using one 807-3366 module<br />
(Item 3) require only one latch relay (Item 5).<br />
Full or dual vat units using two 807-1006,<br />
807-2971, or 807-3365 modules require a<br />
latch relay (Item 5) for each module.<br />
ITEM PART # COMPONENT<br />
1 200-5996 Box Assembly, One-Piece Component<br />
2 807-1006 Ignition Module, Full or Dual Vat (fuse-protected)<br />
* 807-2971 Ignition Module, Full or Dual Vat (fuse-protected) (Australian units only)<br />
3 807-3366 Ignition Module, Full Vat (unfused)<br />
4 807-3365 Ignition Module, Dual Vat (unfused) use 1 wire 1 connector ign. cable 826-2024<br />
5 807-0833 Relay, 12V 5Amp Latch (use Relay Clip 810-2243 to secure relay in place)<br />
* 807-0834 Relay, 12V 5Amp Basket Lift (use Relay Clip 810-2243 to secure relay in place)<br />
6 807-3843 Fuse, 3A 250V Subminature<br />
7 106-0386 Interface Board (double fuse-protected)(use w/ 807-3365, 807-1006 or 807-3366)<br />
* 806-4973 Interface Board (used with 240V manufactured gas units only)<br />
* 806-3683 Interface Board (used with Ger. fryers with 24V blowers only) use 5A fuse 807-3293<br />
* 106-3044 Interface Board, FAST Computer (uses 807-3969 latch relay in place of Item 5)<br />
* 806-3641 Interface Board, (used in Holland)<br />
* 806-4195SP Interface Board, (used with manufactured gas Hong Kong)<br />
* 806-3535 Interface Board, (used in Churches w/ Far West Computers)<br />
8 807-1926 Bushing, .875 Diameter Split<br />
9 816-0217 Paper, Insulating (Items 9, 10, 11, 12 not used on Hong Kong units)<br />
10 810-1164 Block, Terminal (See Item 9)<br />
11 826-1359 Screw, 4-40 x ¾-inch Slotted Round Head (See Item 9) (Pkg. of 25)<br />
12 826-1366 Nut, 4-40 Keps Hex (See Item 9) (Pkg. of 25)<br />
13 807-1241 Spacer, Interface Board (.151-inch ID x ⅝-inch)<br />
14 809-0250 Nut, 6-32 Keps Hex<br />
15 826-1337 Tab, Push-On Terminal (Pkg. of 5)<br />
16 826-1346 Spacer, Ignition Module (.260-inch ID x ½-inch) (Pkg. of 10)<br />
17 809-0441 Screw, #7 x 1½-inch Slotted Washer Hex Head<br />
* 826-1157 Fuse Kit, Ignition Module 3 Amp (fuse and fuse puller)<br />
* 806-2071 Computer Cable 15-pin<br />
* 806-3660 Sound Device (For units with KFC1 Computers, use Speaker 807-1617)<br />
* 807-1359 Mount, Tie-Wrap (used on CE units only)<br />
* Not illustrated.<br />
7<br />
5<br />
4<br />
5<br />
3<br />
4