33. Install the upper oil-zone insulation (21) by pressing it under the upper combustion chamber<br />

metalwork. Secure the insulation with the bracket (22) and ¼” self-tapping screws.<br />

34. Install the upper burner rail blanket insulation (23). Position any excess insulation toward the<br />

top of the frypot. Avoid overhang past the bottom of the upper burner rail. Overhang in this<br />

area will make future burner replacement more difficult.<br />

35. Cover the insulation with the insulation retainer (24), and secure with ¼” self-tapping screws.<br />

36. Reinstall probes, drain valves, high-limit thermostats and other pipefittings using Loctite ®<br />

PST56765 sealant or equivalent on their threads.<br />

1.7 Troubleshooting and Problem Isolation<br />

Because it is not feasible to attempt to include in this manual every conceivable problem or trouble<br />

condition that might be encountered, this section is intended to provide technicians with a general<br />

knowledge of the broad problem categories associated with this equipment, and the probable causes<br />

of each. With this knowledge, the technician should be able to isolate and correct any problem<br />

encountered.<br />

Problems you are likely to encounter can be grouped into seven broad categories:<br />

1. Ignition failures<br />

2. Improper burner functioning<br />

3. Improper temperature control<br />

4. Computer-related problems<br />

5. Filtration problems<br />

6. Leakage<br />

7. Basket lift malfunctions.<br />

The probable causes of each category are discussed in the following sections. A series of Troubleshooting<br />

Guides is also included at the end of the chapter to assist in identifying some of the more<br />

common problems.<br />

1.7.1 Ignition Failures<br />

Ignition failure occurs when the ignition module fails to sense a flame within the 4-second time delay<br />

period and locks out. When this happens, the module sends 24 VAC through the interface board<br />

alarm circuit to the controller/computer.<br />

Analog controllers indicate ignition failure by illuminating the heat light and trouble light<br />

simultaneously. Digital, Computer Magic III, and Basket Lift Timer controls display “H E L p.”<br />

The three primary reasons for ignition failure, listed in order of probability, are:<br />

1. Problems related to the gas and/or electrical power supplies<br />

2. Problems related to the electronic circuits<br />

3. Problems related to the gas valve.<br />

1-21