Figure 2-2. Detail of measurement configuration at the control cell of Site #1<br />

2.1.2 Bioreactor Cell<br />

The bioreactor cell was located on the eastern side of landfill Site #1 (see Figure 1-1). ORS<br />

measurements were collected in this cell on February 22. The bioreactor cell was accepting<br />

waste during the time of the measurements, so it was not possible to deploy the instrumentation<br />

over the entire footprint of the cell due to heavy machinery traffic associated with landfill<br />

operations. The VRPM configuration consisted of a scanning OP-FTIR instrument, a scanning<br />

OP-TDLAS instrument, and two vertical structures. The OP-FTIR was deployed in the<br />

northwestern corner of the cell, the OP-TDLAS was deployed in the southeastern corner of the<br />

cell, and the two vertical structures were deployed in the northeastern and southwestern corners<br />

of the cell, respectively. The work face was located in the eastern portion of the landfill cell.<br />

Figure 2-3 presents a schematic of the measurement configuration used in the Bioreactor Cell,<br />

showing the distances of the VRPM planes. The dashed black lines depict the location of the four<br />

VRPM measurement planes. The dashed yellow line indicates the configuration used to collect<br />

background measurements at the site.<br />