Site #1 5.4<br />

Site #2 77.9<br />

Completeness goals for precision established in the QAPP were not met for monomethyl<br />

mercury sampling and analysis.<br />

5.2.10 DQI Check of VOC Samples with SUMMA® Canisters<br />

Summa® canister samples of the landfill gas were analyzed for the TO-15 list of volatile organic<br />

compounds. Triplicate gas samples and nitrogen sampling system blanks were collected at both<br />

sites. The reported method detection limits for the TO-15 target list was 0.5 ppbv. Data for the<br />

TO-15 gas samples required a flag to designate analytes reported at concentrations less than 5<br />

times the nitrogen blank values due to some background contamination present in the sampling<br />

system. The background contamination in the nitrogen blanks were probably due to carry over<br />

<strong>from</strong> previous landfill gas sampling using the same equipment.<br />

The Summa canister gas samples were also analyzed for methane, CO2, O2, C1 to C-6 alkanes,<br />

NMOC, and N2. The results <strong>from</strong> Methods 25-C appear to be the more consistent with the gas<br />

composition for municipal landfills (U.S. EPA, 2008. Tables 5-8 and 5-9 present the precision<br />

values of the Method 25-C and GC/FID/TCD datasets, respectively.<br />

Table 5-8. Precision ranges for Method 25-C Measurements at Sites #1 and #2<br />

RSD<br />

Methane<br />

(%)<br />

CO2<br />

(%)<br />

NMOC<br />

(%)<br />

Mass Conc.<br />

(%)<br />

Site #1 5.4 4.6 3.8 3.9<br />

Site #2 4.8 4.6 0.9 0.9<br />

Table 5-9. Precision ranges for GC/FID/TCD Measurements at Sites #1 and #2<br />

RSD<br />

Methane<br />

(%)<br />

Oxygen<br />

(%)<br />

Nitrogen<br />

(%)<br />

Carbon Dioxide<br />

(%)<br />

Site #1 75.3 30.6 33.2 19.0<br />

Site #2 2.0 3.3 3.2 0.3<br />

5.3 QC Checks of OP-FTIR Instrument Performance<br />

Several checks should be performed on the OP-FTIR instrumentation prior to deployment to the<br />

field, and during the duration of the field campaign. More information on these checks can be<br />

found in MOP 6802 and 6807 of the ECPD Optical Remote Sensing Facility Manual. Prior to<br />

deployment to the field, the baseline stability, NEA, random baseline noise, saturation, and<br />

single beam ratio tests were performed. The results of the tests indicated that the instrument was<br />

operating within the acceptable criteria range.<br />