5.2.7 DQI Check of Total Mercury Samples<br />

Laboratory control spike recovery for the total mercury sampling during February 2007 was<br />

performed using a NIST 1641D (1.590 mg/kg mercury in water) reference standard. <strong>Two</strong> spike<br />

recoveries were performed with 89.9- and 97.6-percent recovery for an average of 93.8 percent.<br />

Analytical spikes were performed on gas sample two with recoveries of 97.4 and 98.9 percent<br />

with an average recovery of 98.2 percent. Recovery goals established in the QAPP of 50 to 150<br />

percent were met.<br />

Analytical duplicates were performed on gas sample two with values of 150.4 and 160.0 for an<br />

average of 155.2 and a relative percent difference of 6.2 percent. Blank values were less than<br />

0.07 ng per trap with an average of 0.02 ng per trap and an MDL of 0.12 ng per trap.<br />

The precision assessment was performed using data <strong>from</strong> duplicate or replicate samples and<br />

spikes (when available). Precision was expressed as %RPD for samples that were done in<br />

duplicate and as %RSD for samples performed in triplicate. Table 5-4 represents precision values<br />

calculated for total mercury of samples at each site. Precision goals established in the QAPP of<br />