106 MEASUREMENT OF STAGE AND DISCHARGE<br />
The handline is made up of two separate cables that are electrically<br />
connected at a reel (fig. 63). The upper or hand cable is that part ofthe<br />
handline that is used above the water surface. It is a heavy-duty<br />
two-conductor electric cable, whose thick rubber protective covering<br />
makes the cable comfortable to handle. At its upper end is a connection<br />
for the headphone. The lower or sounding cable is a light<br />
reverse-lay steel cable with an insulated core. A connector joins the<br />
lower-end of the sounding cable to the hanger that is used as a mount<br />
for the current meter and sounding weight. Sounding cable in excess<br />
ofthe length needed to sound the stream being measured L, wound on<br />
FIGURE 61.-Handhne,