7. DlSCHARGE-TRACER·DlLUTION METHOD 249<br />

MEASUREMENT OF DISCHARGE BY SODIUM DICHROMATE<br />

DILUTION<br />

GENERAL<br />

In Europe colorimetric analysis, using sodium dichromate<br />

(Na, Cr,O,' 2H,O) as the tracer, is the most widely used means of<br />

measuring discharge by the constant-rate-injection method. Because<br />

colorimetric analysis is rarely used in the U.S.A., the method will be<br />

described here only in brief; detailed descriptions are available in a<br />

report by the International Standards Organization (1973) and in a<br />

paper by Hosegood, Sanderson, and Bridle (1969).<br />

The solubility of sodium dichromate is relatively high-the stock<br />

solution commonly used has a concentration of 600 giL-and the salt<br />

satisfies most oftbe requirements for a tracer that are listed on page<br />

211. Complications resulting from the presence of chromium ions in<br />

the water being gaged seldom occur, because natural waters generally<br />

contain few such ions. However, the nature and quantity of<br />

suspended sediment in the natural water can seriously affect the<br />

accuracy of analysis because of the possibility of sorption of sodium<br />

dichromate by the sediment. Another consideration in the use of<br />

sodium dichromate as a tracer is its potential toxicity to aquatic life,<br />

particularly in localized areas of high concentration; drinkingMwater<br />

standards in the U B.A., for example, recommend a limiting concentration<br />

of 0.05 mg/L for chromium ions (Environmental Protection<br />

Agency, Environmental Studies Board, 1972, p. 62).<br />

The factors that enter into the selection of a reach of channel for a<br />

measurement of discharge by sodium dichromate dilution are identical<br />

with those discussed earlier on pages 215-223. The types of apparatus<br />

for constant-rate-injection-mariotte vessel, floating siphon,<br />

and pressure tank-were described on pages 232-235.<br />

The method of sampling for a discharge measurement by the<br />

constant-rateMinjection method is similar to that described for fluorescent<br />

dyes Cp. 237-240).<br />

PRINCIPLE OF COLORIMETRIC ANALYSIS<br />

Colorimetric analysis permits the measurement of extremely low<br />

concentrations of sodium dichromate. In that type of analysis a colM<br />

orimeter is used to compare (1) the natural dilution ofstream samples<br />

after tracer injection with (2) the known dilution of a stock solution of<br />

the salt. The comparison is based on differences in the absorption of<br />

light by the solutions after a reagent has been added to each of them.<br />

The colorimeter is calibrated by the use of standard solutions, and<br />

it is recommended that the colorimeter used be one that gives a linear