POWER-MASTER 500 - Victor Technologies
POWER-MASTER 500 - Victor Technologies
POWER-MASTER 500 - Victor Technologies
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
2.07 Standard Features<br />
The power source has the following standard features:<br />
a. Short-Circuit Protection – The output of the power<br />
source can be short circuited in any of the modes of<br />
operation. This protection feature will instantly limit<br />
the output current to a safe value, to assure reliable<br />
operation of the power source.<br />
b. Output Overload Protection – The overload protection<br />
feature will limit the continuous weld current to<br />
the maximum value listed in the specifications for any<br />
of the modes of operation. The machine will continue<br />
to operate but the current will be limited to this maximum<br />
value.<br />
c. Cooling Fan Control – The cooling fans are designed<br />
to operate only when required. They will come on<br />
whenever the output contactor control of the machine<br />
is on. The fans will come on for several minutes when<br />
the machine is first turned on and will normally stay<br />
on for several minutes after the output contactor control<br />
has been switched off. The fans will turn off after<br />
several minutes of inactivity, to minimize the amount<br />
of dirt being drawn into the machine, as well as<br />
lengthen the life of the fans.<br />
d. Overtemperature Protection – If the machine overheats<br />
because of blocked air flow, excessive ambient<br />
temperatures, failed fan, or other cause, the<br />
overtemperature protection will disable the output of<br />
the power source until it has cooled down. If the<br />
overtemperature protection circuit operates, it will<br />
turn on the indicator light on the front panel and the<br />
fans should continue to run until the machine cools.<br />
The overtemperature circuit will reset itself automatically<br />
once the machine has cooled.<br />
e. Multi-Voltage Operation – The power source is designed<br />
to operate from a wide range of input line voltages<br />
as given in the specifications. The machine can<br />
be reconfigured for the different line voltages with a<br />
simple, rugged voltage changeover panel accessible<br />
from the rear panel of the machine (see Installation<br />
chapter for detailed instructions).<br />
f. Multi-Process Operation – The machine has built in<br />
electronic controls which have been optimized for<br />
most welding processes. The following controls are<br />
standard: GTAW with Lift Start, SMAW, CAG,<br />
GMAW/FCAW including the short-arc, globular and<br />
spray transfer modes. Each mode of operation has a<br />
dedicated electronic control which has been optimized<br />
for that particular process.<br />
MANUAL 430429-485 2-5 INTRODUCTION