Material: (nominally for one sensor installation)<br />

Item Description<br />

Minimum<br />

Quantity<br />

1 <strong>Capacitive</strong> WIM sensor As required<br />

2 <strong>Installation</strong> frame As required<br />

3 Support brackets for installation 1 set<br />

3 <strong>Installation</strong> frame kit complete (shims, bolts, anchors, earth wire) As required<br />

4 20 liter epoxy kit (10 L part A and 10 L part B) per sensor As required<br />

5 50 kg clean dry silica filler sand As required<br />

6 5 litre acetone cleaner As required<br />

7 Sealing putty (500 gm) As required<br />

8 Silicone sealant (one tube) As required<br />

9 Loctite 243 medium strength 1 medium<br />

10 Flexible seal (ABE hot-melt) or equivalent 10 kg As required<br />

11 20 spare 10 mm x 20 bolts for blocking mounting holes As required<br />

12 Release agent (500gm beeswax clear polish) 1<br />

Equipment:<br />

Item Description<br />

Minimum<br />

Quantity<br />

1 Pavement breaker with 20mm and 40mm bit (adequate strength) 1<br />

2 25mm diameter 300mm long concrete drill bit 1<br />

3 Straight-edge (3m) 1<br />

4 Torque wrench (100 N*m) 1<br />

5 Steel rule and or graded wedge 1<br />

6 Disposable gloves 50<br />

7 Bucket measure (15 liter) 4<br />

8 Mixing bucket (25 liter minimum) (clean and uncontaminated) 2<br />

9 Tarpaulin (10m x 5m) 1<br />

8 Spiral mixing paddle 1<br />

9 Hilti (Kango) hammer action drill (adequate size) 1<br />

10 10mm Tap set (with cleaning tap) 1<br />

Test equipment:<br />

All equipment as listed in loop installation document<br />

Item Description<br />

Minimum<br />

Quantity<br />

1 Mikros Systems Weighing Logger 1<br />

2 Laptop with Telcom 1<br />

3 Infrared thermometer 1<br />

MS001-96100-52 <strong>Installation</strong> <strong>of</strong> <strong>Fixed</strong> <strong>Capacitive</strong> <strong>HSWIM</strong> <strong>Sensors</strong> Issue5 1 March 2005<br />