Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>ARTDrive</strong><br />
Ordering Codes<br />
Output Chokes<br />
Induttanze di Uscita<br />
Inductances de Sortie<br />
Ausgangsdrosseln<br />
Inductancia de Salida<br />
Refer to the Appendix for choke weights and dimensions.<br />
Per le dimensioni e i pesi delle induttanze vedere<br />
Appendice.<br />
Pour les dimensions et les poids des inductances voir<br />
Appendice<br />
Für die Abmessungen und Gewichte der Netzdrosseln<br />
siehe Anhang.<br />
Ver el Apéndice para dimensiones y pesos de las<br />
inductancias.<br />
Drive type<br />
AVy1007<br />
AVy1015<br />
AVy1022<br />
AVy1030<br />
AVy2040<br />
AVy2055<br />
AVy2075<br />
AVy3110<br />
AVy3150<br />
AVy4220<br />
AVy4300<br />
AVy4370<br />
AVy5450<br />
AVy5550<br />
AVy6750<br />
AVy7900<br />
AVy71100<br />
AVy71320<br />
AVy81600<br />
AVy92500<br />
AVy93150<br />
AVy104000<br />
AVy105000<br />
AVy106300<br />
Drive type<br />
AVy2002<br />
AVy2003<br />
AVy2005<br />
AVy3007<br />
AVy3010<br />
AVy3015<br />
AVy3020<br />
AVy4025<br />
AVy4030<br />
AVy4040<br />
AVy5050<br />
AVy5060<br />
AVy5075<br />
AVy6100<br />
AVy7125<br />
AVy7150<br />
AVy8200<br />
Rated<br />
choke<br />
[mH]<br />
76 www.sieigroup.com <strong>ARTDrive</strong> <strong>Catalogue</strong><br />
1.4<br />
1.4<br />
1.4<br />
1.4<br />
0.87<br />
0.87<br />
0.51<br />
0.51<br />
0.43<br />
0.33<br />
0.24<br />
0.18<br />
0.12<br />
0.12<br />
0.07<br />
0.07<br />
0.041<br />
0.041<br />
0.041<br />
0.022<br />
0.022<br />
Rated<br />
choke<br />
[mH]<br />
3<br />
3<br />
1.9<br />
1<br />
1<br />
0.64<br />
0.64<br />
0.51<br />
0.43<br />
0.34<br />
0.27<br />
0.22<br />
0.18<br />
0.14<br />
0.11<br />
0.11<br />
0.070<br />
AVy… (230…480V)<br />
Rated<br />
current<br />
[A]<br />
9.5<br />
9.5<br />
9.5<br />
9.5<br />
16<br />
16<br />
27<br />
27<br />
32<br />
42<br />
58<br />
76<br />
110<br />
110<br />
180<br />
180<br />
310<br />
310<br />
310<br />
580<br />
580<br />
AVy … -5 (575V)<br />
Rated<br />
current<br />
[A]<br />
4.5<br />
4.5<br />
7<br />
13,8<br />
13,8<br />
24,2<br />
24,2<br />
30<br />
36<br />
46<br />
58<br />
69<br />
86<br />
109<br />
158<br />
158<br />
220<br />
Saturation<br />
current<br />
[A]<br />
20<br />
20<br />
20<br />
20<br />
34<br />
34<br />
57<br />
57<br />
68<br />
72<br />
100<br />
130<br />
192<br />
192<br />
310<br />
310<br />
540<br />
540<br />
540<br />
1100<br />
1100<br />
For information refer to SIEI commercial Offices<br />
Saturation<br />
current<br />
[A]<br />
8.5<br />
8.5<br />
13<br />
25.3<br />
25.3<br />
44.3<br />
44.3<br />
54.9<br />
65.9<br />
84.2<br />
106.1<br />
126.3<br />
157.4<br />
200<br />
290<br />
290<br />
403<br />
Model<br />
Number<br />
LU3-003<br />
LU3-003<br />
LU3-003<br />
LU3-003<br />
LU3-005<br />
LU3-005<br />
LU3-011<br />
LU3-011<br />
LU3-015<br />
LU3-022<br />
LU3-030<br />
LU3-037<br />
LU3-055<br />
LU3-055<br />
LU3-090<br />
LU3-090<br />
LU3-160<br />
LU3-160<br />
LU3-160<br />
LU3-315<br />
LU3-315<br />
LU3-630<br />
LU3-630<br />
LU3-630<br />
Model<br />
Number<br />
LU3-5-003<br />
LU3-5-003<br />
LU3-5-005<br />
LU3-5-010<br />
LU3-5-010<br />
LU3-5-020<br />
LU3-5-020<br />
LU3-5-025<br />
LU3-5-030<br />
LU3-5-040<br />
LU3-5-050<br />
LU3-5-060<br />
LU3-5-075<br />
LU3-5-100<br />
LU3-5-150<br />
LU3-5-150<br />
LU3-5-200<br />
SIEI code<br />
S7FG2<br />
S7FG2<br />
S7FG2<br />
S7FG2<br />
S7FG3<br />
S7FG3<br />
S7FG4<br />
S7FG4<br />
S7FM2<br />
S7FH3<br />
S7FH4<br />
S7FH5<br />
S7FH6<br />
S7FH6<br />
S7FH7<br />
S7FH7<br />
S7FH8<br />
S7FH8<br />
S7FH8<br />
S7FH9<br />
S7FH9<br />
S7FI1<br />
S7FI1<br />
S7FI1<br />
SIEI code<br />
When controlled by inverters and connected over excessive distances (usually anything in excess of 100 metres), standard motors might require use of an output choke to<br />
help maintain the voltage waveform within acceptable limits.<br />
I motori standard, se controllati tramite inverter e collegati a distanze eccessive (solitamente oltre i 100 metri) possono richiedere un induttore d'uscita, allo scopo di<br />
mantenere la forma d'onda di tensione entro i limiti ammessi.<br />
Les moteurs standard, s'ils sont contrôlés par un variateur et reliés par des câbles de grande longueur (généralement plus de 100 mètres) peuvent exiger une inductance<br />
de sortie, afin de maintenir la forme d'onde de tension dans les limites acceptables.<br />
Wenn Standardmotoren durch Frequenzumrichter gesteuert werden, und in grösseren Entfernungen zueinander angeschlossen sind (normalerweise über 100 Meter), kann<br />
eine Ausgangsdrossel erforderlich sein, damit die Spannungswellenform innerhalb der zulässigen Beschränkungen bleibt.<br />
Cuando los motores son controlados o conectados a excesiva distancia, (normalmente todo lo que exceda de 100metros), requieren el uso de una inductancia de salida<br />
para ayudar a mantener la forma de onda de tensión en unos límites aceptables.<br />
S7FI2<br />
S7FI2<br />
S7FI3<br />
S7FI4<br />
S7FI4<br />
S7FI5<br />
S7FI5<br />
S7FI6<br />
S7FI7<br />
S7FI8<br />
S7FI9<br />
S7FL0<br />
S7FL1<br />
S7FL4<br />
S7FL5<br />
S7FL5<br />
S7FL6