HR6 Series.pdf - Genius
HR6 Series.pdf - Genius
HR6 Series.pdf - Genius
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Service<br />
Guide<br />
ColorPage-<strong>HR6</strong>/<strong>HR6</strong> V2/<strong>HR6</strong>X series<br />
1.2.2. TPA lamp unilluminated<br />
Problem<br />
TPA lamp unilluminated<br />
Analyze the<br />
Problem<br />
(1) Mechanical<br />
(2) Electronic<br />
(1-1) (1-2) (2-1) (2-2)<br />
Identify the<br />
Problem Causes<br />
Broken or<br />
Defective Lamp<br />
Burned out or<br />
Defective<br />
Inverter<br />
TPA wire is not<br />
attached to Scan<br />
Board<br />
Defective<br />
Scan Board<br />
Solutions<br />
Replace Lamp<br />
Replace<br />
Inverter<br />
Re-attach<br />
the wire<br />
Replace<br />
Scan Board<br />
Version: 1.0<br />
Page 10/59