Motortronics<br />

Register<br />

Address<br />

Register<br />

Name<br />

Data<br />

Range<br />

Data<br />

<strong>Inc</strong>r.<br />

Data<br />

Default<br />

R/W Remark Setpoint<br />

<strong>Inc</strong>.<br />

Setpoint<br />

Default<br />

1087 Modbus Address 1 - 247 1 1 1 1<br />

1088 Year 2000 - 2047 1 year - 1 year -<br />

1089 Month 1-12 1 Month - 1 Month -<br />

1090 Day 1-31 1 Day - 1 Day -<br />

1091 Hour 0 - 23 1 Hour - 1 Hour -<br />

1092 Minute 0 - 59<br />

1093 Seconds 0 - 59<br />

1<br />

Minute<br />

1<br />

Second<br />

- 1 Minute -<br />

- 1 Second -<br />

1094 Default Display 0-34 1 1 1 1<br />

1095 Unit of Temperature 0-1 1 0<br />

Redo RTDs trip<br />

and alarm<br />

setting, if change<br />

here.<br />

1 0<br />

1096 Relay 1 Fail Safe 0-1 1 0 1 0<br />

1097 Relay 2 Fail Safe 0-1 1 0 1 0<br />

1098 Relay 3 Fail Safe 0-1 1 0 1 0<br />

1099 Relay Test<br />

0-3<br />

1 0 1 0<br />

1100<br />

Parameter Lock/ Level 1<br />

Password<br />

0, 001 –<br />

999<br />

1<br />

0(Show<br />

encrypte<br />

d code)<br />

1<br />

0(Show<br />

encrypted<br />

code)<br />

System Clear / Factory Reset<br />

1101 (Reset Factory Default<br />

Settings)<br />

1102 Level 2 Password<br />

1103 Reserved<br />

0, 1 – 4<br />

2000 –<br />

9999<br />

1 0 1 0<br />

2000<br />

1 2000 1<br />

(Show<br />

encrypted<br />

code)<br />

1104 <strong>RTD12</strong> Revision # - - - Read Only - -<br />

1105 KP Revision # - - - Read Only - -<br />

1106 RTD-INF Revision# - - - Read Only - -<br />

1107 Fault History #1, Latest Fault 0,31 – 50 1 0 Read Only 1 0<br />

1108<br />

Alarm / Trip Level (if<br />

available)<br />

1109 Time Stamp, Fault #1<br />

0 - 9999 1 - Read Only - -<br />

00.00-23.59<br />

00.01 00.00 Read Only 00.01 00.00<br />

1110 Date Stamp, Fault #1<br />

01.01 –<br />

12.31<br />

00.01 01.01 Read Only 00.01 01.01<br />

1111<br />

1112<br />

Fault History #2, Previous<br />

Fault<br />

Alarm / Trip Level (if<br />

available)<br />

0, 31 – 50 1 0 Read Only 1 0<br />

0 - 9999 1 - Read Only - -<br />

www.motortronics.com Page 52