Demo #3708 Smeal <strong>Fire</strong> Apparatus Co. 105’ Heavy Duty <strong>Aerial</strong><br />

TANK FILL VALVE<br />

There shall be one (1) 2" full-flow tank fill valve plumbed with 2" plumbing from the pump to the<br />

tank. Installation shall be completed with 2" Class1 rubber hose and stainless steel hose<br />

couplings. The tank fill valve shall be controlled from the operator's control panel.<br />

PAINT PUMP - GRAY<br />

The pump body shall be painted with PPG polyurethane enamel paint. The paint color shall be a<br />

neutral gray. The pump enclosure shall be painted the same color as the apparatus body.<br />

GATED SUCTION INLETS<br />

All suction valves, unless otherwise noted in the specifications, shall be Akron 8800 series brass,<br />

quarter-turn, full flow, and swing-out type. Each valve shall be designed in such a manner that the<br />

action of water against the regulating element shall not affect its position.<br />

Each valve shall be individually attached to the manifold of the pump with stainless steel pipe. The<br />

plumbing to the valve shall contain a minimum of elbows to keep friction loss to a minimum.<br />

The valves located in the pump compartment area shall be partially recessed behind the panel with<br />

the portion of the valve that contains water protected from the elements.<br />

INTAKE DRAINS<br />

Each gated intake shall be equipped with a Trident Emergency 3/4" quarter turn bleeder valve.<br />

The bleeder valve shall be equipped with a chrome plated rectangular handle to provide a positive<br />

grip while personnel are wearing gloves.<br />

INTAKE TRIM PLATES<br />

Each gated intake shall have a polished cast aluminum trim plate around the intake valve and<br />

fitting. The trim plate shall be easily removable without the need to disturb the valve.<br />

SLOW CLOSE MECHANISMS<br />

Gated intakes that are 3" or larger shall be equipped with a mechanism to prevent changing the<br />

position of the valve from full open to full close, or vice-versa, in less than 3 seconds.<br />

INTAKE STRAINERS<br />

Removable strainers shall be provided with each gated intake.<br />

LEFT SIDE 2-½" GATED INTAKE(S) - PARTIALLY RECESSED<br />

There shall be one (1) 2-½" gated intake(s) provided on the left side of the pump compartment.<br />

The intake shall be furnished with a 2-½" valve and 2-½" plumbing. The intake shall terminate with<br />

a 2-½" NST female chrome swivel. The associated bezel shall be black.<br />

The suction valve(s), unless otherwise noted in the specifications, shall be an Akron 8800 series<br />

brass, quarter-turn, full flow, and swing-out type. The valve shall be designed in such a manner<br />

that the action of water against the regulating element shall not affect its position.<br />

Each valve shall be individually attached to the manifold of the pump with stainless steel pipe. The<br />

plumbing to the valve shall contain a minimum of elbows to keep friction loss to a minimum.<br />