Demo #3708 Smeal <strong>Fire</strong> Apparatus Co. 105’ Heavy Duty <strong>Aerial</strong><br />

Onan shall pay travel time up to two and one-half (2.5) hours and mileage cost up to one hundred<br />

(100) miles, if such work is done by an Onan distributor or other service representative designated<br />

by Onan.<br />

The generator shall be located above pump.<br />

GENERATOR DISPLAY METER<br />

There shall be an LED generator display meter provided with the generator. The display meter<br />

shall automatically sense a generator signal and begin displaying information. The digital meter<br />

display shall constantly monitor and display voltage, frequency and amps. The display shall be<br />

capable of displaying total accumulated run time hours when the MODE button is pressed once.<br />

Press the MODE button twice to display the temperature of the oil returning to the oil reservoir.<br />

The frog display shall be located on the pump panel.<br />

LOAD CENTER<br />

The entire 120/240 volt electrical system shall be installed in strict compliance with NFPA Pamphlet<br />

1901, newest edition. This shall include all testing, labeling, wiring methodology, and dimensional<br />

requirements. Certification of compliance shall accompany the apparatus at the time of delivery.<br />

There shall be a 120/240 volt load center incorporated into the 120/240 volt wiring system. The<br />

load center shall include adequate circuit breakers to protect the loads specified on this apparatus.<br />

All 120/240 volt A.C. Wiring shall be done in accordance with NFPA Pamphlet 1901 as well as<br />

nationally accepted electrical codes.<br />

BRANCH CIRCUIT OVERCURRENT PROTECTION<br />

Over current protection devices shall be provided for circuits in accordance with NFPA 1901<br />

newest version. The load center shall be equipped with a non-GFI two pole main breaker when the<br />

six or more individual branch circuits are present.<br />

Over current protection devices shall be marked with labels to identify the function of the circuit<br />

they protect.<br />

The load center shall be located L-1.<br />

LOAD CENTER ROLL UP DOOR DRIP TRAY, ROM<br />

There shall be a drip pan with drain provided in the upper section of the compartment. The drip<br />

pan shall prevent moisture from the roll-up door spool from coming in contact with the breaker box.<br />

120 VOLT TWIST LOCK RECEPTACLE(S)<br />

There shall be two (2) NEMA L5-20, 120 Volt 20 ampere rating Twist Lock type receptacle(s) wired<br />

to the generator. The receptacle(s) shall have a spring loaded weather resistant cover.<br />

The receptacle(s) shall be located one (1) each side ahead of the drive axle.<br />

TELESCOPING 120 VOLT LIGHTS<br />

There shall two (2) Havis-Shields telescoping light pole, part number KR-SB-356, comprised of the<br />

following components shall be supplied.<br />

Revised 3/19/09 Page 42 of 112