Demo #3708 Smeal <strong>Fire</strong> Apparatus Co. 105’ Heavy Duty <strong>Aerial</strong><br />
Onan shall pay travel time up to two and one-half (2.5) hours and mileage cost up to one hundred<br />
(100) miles, if such work is done by an Onan distributor or other service representative designated<br />
by Onan.<br />
The generator shall be located above pump.<br />
GENERATOR DISPLAY METER<br />
There shall be an LED generator display meter provided with the generator. The display meter<br />
shall automatically sense a generator signal and begin displaying information. The digital meter<br />
display shall constantly monitor and display voltage, frequency and amps. The display shall be<br />
capable of displaying total accumulated run time hours when the MODE button is pressed once.<br />
Press the MODE button twice to display the temperature of the oil returning to the oil reservoir.<br />
The frog display shall be located on the pump panel.<br />
LOAD CENTER<br />
The entire 120/240 volt electrical system shall be installed in strict compliance with NFPA Pamphlet<br />
1901, newest edition. This shall include all testing, labeling, wiring methodology, and dimensional<br />
requirements. Certification of compliance shall accompany the apparatus at the time of delivery.<br />
There shall be a 120/240 volt load center incorporated into the 120/240 volt wiring system. The<br />
load center shall include adequate circuit breakers to protect the loads specified on this apparatus.<br />
All 120/240 volt A.C. Wiring shall be done in accordance with NFPA Pamphlet 1901 as well as<br />
nationally accepted electrical codes.<br />
BRANCH CIRCUIT OVERCURRENT PROTECTION<br />
Over current protection devices shall be provided for circuits in accordance with NFPA 1901<br />
newest version. The load center shall be equipped with a non-GFI two pole main breaker when the<br />
six or more individual branch circuits are present.<br />
Over current protection devices shall be marked with labels to identify the function of the circuit<br />
they protect.<br />
The load center shall be located L-1.<br />
LOAD CENTER ROLL UP DOOR DRIP TRAY, ROM<br />
There shall be a drip pan with drain provided in the upper section of the compartment. The drip<br />
pan shall prevent moisture from the roll-up door spool from coming in contact with the breaker box.<br />
120 VOLT TWIST LOCK RECEPTACLE(S)<br />
There shall be two (2) NEMA L5-20, 120 Volt 20 ampere rating Twist Lock type receptacle(s) wired<br />
to the generator. The receptacle(s) shall have a spring loaded weather resistant cover.<br />
The receptacle(s) shall be located one (1) each side ahead of the drive axle.<br />
TELESCOPING 120 VOLT LIGHTS<br />
There shall two (2) Havis-Shields telescoping light pole, part number KR-SB-356, comprised of the<br />
following components shall be supplied.<br />