209<br />
If the customer does not have special<br />
requirements as regards the presentation<br />
<strong>of</strong> reliability data, Ericsson usually<br />
provides a separate report with data<br />
concerning:<br />
- failure rate and MTBF <strong>for</strong> individual<br />
function blocks (e.g. magazine or<br />
shelf)<br />
- failure rate, MTBF, trustworthiness<br />
reliability, availability and down time<br />
<strong>for</strong> a selected, worst case system or<br />
link combination<br />
- failure rate and MTBF <strong>for</strong> the whole<br />
equipment quoted <strong>for</strong><br />
- maximum number <strong>of</strong> failures <strong>for</strong><br />
equipment in accordance with the<br />
two previous items, which with a certain<br />
probability will not be exceeded<br />
during a given period <strong>of</strong> time<br />
- the prediction method and its trustworthiness<br />
These data are a best estimate, and in<br />
the case <strong>of</strong> a guarantee a higher confidence<br />
level is chosen. The amount <strong>of</strong><br />
equipment, operating conditions and<br />
verification methods must also be carefully<br />
specified.<br />
There are different methods and models<br />
<strong>for</strong> verifying that the equipment meets<br />
the guaranteed reliability. In all cases,<br />
however, the test plan must define:<br />
- the equipment to be tested<br />
- the beginning and end <strong>of</strong> the test<br />
period<br />
- operating conditions and failure concepts<br />
- statistical evaluation method.<br />
The text in the technical part <strong>of</strong> the guarantee<br />
should be clear, unambiguous<br />
and easy to understand, and only contain<br />
data that can easily be checked. It<br />
could be <strong>for</strong>mulated as follows:<br />
"An MTBF>6.7 years is guaranteed <strong>for</strong><br />
the specified equipment, i.e. a failure<br />
rate z