You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Extension to the DALI program<br />
8 inputs<br />
Light Server<br />
Push-buttons/switches<br />
The current generation of ERCO’s<br />
Light Servers now has a total of<br />
8 inputs – four of them can be<br />
used exclusively as digital/switch<br />
inputs, the other four optionally<br />
as digital/switch inputs or as<br />
analogue inputs. This extends<br />
the range of scenarios through<br />
which Light System DALI can<br />
be controlled not only with conventional<br />
switches and pushbuttons<br />
but also with analogue<br />
and digital sensors.<br />
8 inputs<br />
Sensors<br />
Light Server<br />
Push-buttons<br />
Digital/switch inputs<br />
Up to 8 digital/switch inputs can<br />
be assigned different functions,<br />
such as the recall of a specific<br />
light scene or sequence, a list of<br />
light scenes running as a progression<br />
on repeated operation, but<br />
also master dimming up and down.<br />
Each input can be assigned<br />
one push-button or have several<br />
connected in parallel. The model<br />
and the functions to be triggered<br />
are specified in the Light Book<br />
module of the Light Studio software<br />
or, alternatively to the scene<br />
selection, via the user-friendly<br />
Light Changer. This allows a wide<br />
range of other scenarios through<br />
which the Light System DALI can<br />
be controlled. In a room with more<br />
than one entrance, for example,<br />
each door can have a standard<br />
push-button panel recalling the<br />
same predefined light scenes. It<br />
is possible to continue using the<br />
exist ing switch and push-button<br />
installations, while a rocker switch<br />
can control the master dimming<br />
function.<br />
Other applications for digital/<br />
switch inputs include the connection<br />
of different digital sensors<br />
such as motion sensor or twilight<br />
switch.<br />
Light Changer<br />
Push-buttons<br />
1 2<br />
3 4<br />
5 6<br />
Push-buttons<br />
1 2<br />
3 4<br />
5 6<br />
7 8<br />
The Light System<br />
DALI can be connected<br />
to any<br />
standard switch<br />
or push-button<br />
to recall scenes,<br />
scene lists, or<br />
sequences.<br />
Room with three entrances<br />
In this example<br />
of use, the pushbutton<br />
panels at<br />
the doors have<br />
been assigned<br />
predefined light<br />
scenes. For more<br />
complex operating<br />
steps, the<br />
room has also<br />
been provided<br />
with a Light<br />
Changer.<br />
8 ERCO <strong>New</strong> <strong>Products</strong> 2009 www.erco.com