Dimensional Data<br />
Standard Duty Arrangement 10<br />
Rotatable Housing — Sizes 12" through 39"<br />
S<br />
P<br />
R<br />
R<br />
9 /16 DIA. HOLES<br />
PLAN VIEW<br />
OF BASE<br />
T<br />
U<br />
T<br />
U<br />
C<br />
B<br />
K<br />
N<br />
H<br />
M<br />
J<br />
F<br />
E<br />
D<br />
AIRFLOW<br />
L<br />
I.D.<br />
AIRFLOW<br />
A<br />
G<br />
MODEL<br />
DIMENSIONS (IN.)<br />
NO. A B C D a b c d E F G H (MAX.)<br />
12 20 5 ⁄8 10 9 5 ⁄8 7 5 ⁄32 9 1 ⁄16 14 5 ⁄8 10 3 ⁄16 7 15 ⁄16 7 13 ⁄32 10 3 ⁄4 8 17 ⁄32 29 9 ⁄32<br />
14 24 1 ⁄8 11 10 27 ⁄32 7 25 ⁄32 10 1 ⁄4 16 5 ⁄16 11 7 ⁄16 9 8 11 ⁄32 12 3 ⁄32 9 9 ⁄32 33 17 ⁄32<br />
16 24 1 ⁄8 12 12 3 ⁄16 8 19 ⁄32 11 7 ⁄16 18 1 ⁄16 12 7 ⁄8 10 1 ⁄8 9 3 ⁄8 13 19 ⁄32 10 25 ⁄32 34 9 ⁄32<br />
18 27 3 ⁄4 13 13 23 ⁄32 9 15 ⁄32 12 13 ⁄16 20 1 ⁄32 14 1 ⁄2 11 1 ⁄4 10 9 ⁄16 15 5 ⁄16 12 1 ⁄8 39 15 ⁄32<br />
20 27 3 ⁄4 14 3 ⁄32 15 9 ⁄32 10 11 ⁄16 14 5 ⁄16 22 16 9 ⁄32 12 5 ⁄8 11 3 ⁄4 17 1 ⁄32 13 17 ⁄32 40 15 ⁄32<br />
22 30 15 1 ⁄2 17 3 ⁄32 11 31 ⁄32 16 1 ⁄16 24 7 ⁄16 18 1 ⁄16 14 1 ⁄8 13 5 ⁄32 19 3 ⁄32 15 1 ⁄8 44 9 ⁄16<br />
25 34 1 ⁄8 18 1 ⁄8 19 7 ⁄32 13 19 ⁄32 18 1 ⁄8 27 15 ⁄16 20 5 ⁄16 15 15 ⁄16 14 25 ⁄32 21 7 ⁄16 17 49<br />
28 34 1 ⁄8 20 1 ⁄4 21 21 ⁄32 15 3 ⁄32 20 3 ⁄8 31 1 ⁄2 22 13 ⁄16 17 15 ⁄16 16 21 ⁄32 24 5 ⁄32 19 5 ⁄32 51 5 ⁄16<br />
32* 34 1 ⁄8 22 1 ⁄16 24 3 ⁄8 16 7 ⁄8 23 1 ⁄8 34 7 ⁄8 25 13 ⁄16 20 5 ⁄16 18 3 ⁄4 27 3 ⁄16 21 9 ⁄16 53 5 ⁄8<br />
35* 37 24 5 ⁄8 27 3 ⁄8 18 15 ⁄32 25 3 ⁄4 39 28 7 ⁄8 22 11 ⁄16 21 1 ⁄32 30 5 ⁄16 24 7 ⁄32 55 15 ⁄16<br />
39* 37 26 3 ⁄4 30 7 ⁄16 20 25 ⁄32 28 13 ⁄16 42 15 ⁄16 32 1 ⁄4 25 5 ⁄16 23 13 ⁄32 33 31 ⁄32 26 29 ⁄32 58 1 ⁄32<br />
DIMENSIONS (IN.) BASE MAX.<br />
MODEL<br />
K<br />
HOLE MOTOR<br />
NO. J<br />
L M N P R S T U<br />
(MAX.) DIA. FRAME<br />
12 3 3 5 ⁄16 7 1 ⁄4 6 5 ⁄32 16 1 ⁄2 25 31 ⁄32 4 1 ⁄16 16 8 3 ⁄8 9 9<br />
⁄16 184T<br />
14 3 4 1 ⁄8 8 1 ⁄32 6 29 ⁄32 19 1 ⁄2 29 19 ⁄32 4 7 ⁄16 19 9 3 ⁄8 10 9<br />
⁄16 215T<br />
16 3 4 8 31 ⁄32 7 25 ⁄32 19 1 ⁄2 30 19 ⁄32 4 7 ⁄8 19 9 7 ⁄8 10 1 ⁄2 9<br />
⁄16 215T<br />
18 3 4 3 ⁄4 10 8 23 ⁄32 23 34 29 ⁄32 5 3 ⁄8 22 1 ⁄2 10 7 ⁄8 11 1 ⁄2 9<br />
⁄16 256T<br />
20 3 4 3 ⁄4 11 3 ⁄16 9 23 ⁄32 23 35 29 ⁄32 5 7 ⁄8 22 1 ⁄2 11 5 ⁄8 12 1 ⁄4 9<br />
⁄16 256T<br />
22 3 5 11 ⁄16 12 9 ⁄16 10 7 ⁄8 25 38 7 ⁄8 6 7 ⁄16 24 1 ⁄2 12 7 ⁄8 13 1 ⁄2<br />
11<br />
⁄16 286T<br />
25 4 5 5 ⁄16 14 1 ⁄8 12 3 ⁄16 27 1 ⁄2 43 11 ⁄16 7 7 ⁄32 26 15 ⁄16 14 3 ⁄8 15 1 ⁄4<br />
11<br />
⁄16 326T<br />
28 4 6 1 ⁄8 15 29 ⁄32 13 11 ⁄16 27 1 ⁄2 45 3 ⁄8 8 1 ⁄8 26 15 ⁄16 16 3 ⁄4 17 5 ⁄8<br />
11<br />
⁄16 326T<br />
32* 4 6 3 ⁄4 17 7 ⁄8 15 3 ⁄8 27 1 ⁄2 46 7 ⁄8 8 13 ⁄16 13 5 ⁄8 16 5 ⁄8 17 1 ⁄2<br />
13<br />
⁄16 326T<br />
35* 4 7 3 ⁄16 19 27 ⁄32 17 1 ⁄4 27 1 ⁄2 48 3 ⁄4 9 3 ⁄4 13 5 ⁄8 18 5 ⁄8 19 1 ⁄2<br />
13<br />
⁄16 326T<br />
39* 4 7 1 ⁄4 22 7 ⁄32 19 9 ⁄32 27 1 ⁄2 50 3 ⁄4 10 3 ⁄4 13 5 ⁄8 20 1 ⁄2 21 3 ⁄8<br />
13<br />
⁄16 326T<br />
*Fixed Housing, Not Rotatable<br />
D, L, and M are outside dimensions. For inlet and<br />
outlet areas (I.D.), see rating tables.<br />
DIMENSIONS ARE NOT TO BE USED FOR CONSTRUCTION.<br />
50 <strong>Aerovent</strong> Bulletin 705