21.04.2014 Views

Qhafor Ameen Hamasur

Qhafor Ameen Hamasur

Qhafor Ameen Hamasur

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

(deformation modulus of the dam / deformation modulus of the foundation rocks),<br />

(2) they are desirable for excavation, (3) they need no or spot grouting and (4) they<br />

have no deformability problems (except one rock mass unit), while the rock mass<br />

units of clastic Kolosh Formation in the boreholes at the left side of Basara gorge:<br />

(1) have some important problems that can't be neglected especially if the dam type<br />

is Conventional Vibrated Concrete (CVC – Gravity), (2) they are less desirable for<br />

gravity dam, (3) they need systematic grouting especially in the case of gravity dam<br />

and (4) they have serious deformability problems especially in the case of gravity<br />

dam construction.<br />

Rock mass classification systems and Hoek – Brown failure criterion results<br />

reveal that the limestone rock mass units of Sinjar Formation at the right side and of<br />

Kolosh Formation in the boreholes at the left side of Basara gorge are characterized<br />

by high values of RMR, DMR & GSI and better mechanical properties, but the rock<br />

mass units of clastic Kolosh Formation at the left side and Gercus Formation at the<br />

right side of Basara gorge are characterized by low – intermediate values of RMR,<br />

DMR and GSI and worse mechanical properties.<br />

This study proposes a new model which is called rock mass – valley section<br />

model in this thesis and applied here for the three profiles (a-b, c-d & e-f profiles)<br />

which are drawn for the first time, in which the rock mass units are projected into<br />

each section.<br />

Comparisons among these profiles for choosing the optimum one revealed that<br />

the e-f profile is better than c-d profile in most aspects and c-d profile is better than<br />

a-b profile, but the final comparison between e-f and c-d profiles revealed that the c-<br />

d profile is more suitable than e-f profile, due to the presence of a weak sheared<br />

zone in the right side of e-f profile which has a great negative effect on the stability of<br />

the dam after construction and filling the reservoir and causes instability which<br />

increases with time.<br />

II

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!