FS-C8026N Service Manual - kyocera
FS-C8026N Service Manual - kyocera
FS-C8026N Service Manual - kyocera
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
2BF-3<br />
<strong>Service</strong> items<br />
Description<br />
Items<br />
Description<br />
(37) Media type attributes Media type setting value from 1 to 28 (fuser temperature,<br />
paper thickness, duplex printing)<br />
(14 to 20 are unused and always 0x00.)<br />
(38) Memory SPD information (slot 1) Bus error if all digits are "E".<br />
(39) Memory SPD information (slot 2) Bus error if all digits are "E".<br />
(40) Calibration prohibition setting 0: Permit 1: Prohibit<br />
(41) Calibration information /Background value (S-wave) /Background value (Pwave)/Dark<br />
current (S-wave) /Dark current (P-wave)/Bias<br />
data magenta/cyan/yellow/black/Overabundance value<br />
(S-wave) /Overabundance value (P-wave) /Performance/<br />
E00: Normal<br />
E10: Sensor value is not a monotonous increase<br />
E11: Few amounts of increases of a sensor value<br />
E12: Sensor value is not a monotonous increase and few<br />
amounts of increases<br />
E20: Calibration discontinuance request from engine controller<br />
PWB<br />
(42) Measure bias data Max 0%/ 85%/ 40%/ High 0%/ 85%/ 40%/<br />
Middle 0%/ 85%/ 40%/ Max 0%/ 85%/ 40%/<br />
Lower 0%/ 85%/ 40%/ Min 0%/ 85%/ 40%/<br />
CT02 to CT09: First time<br />
CT20 to CT27: Second time<br />
CT02/CT20: Magenta, S-wave<br />
CT03/CT21: Cyan, S-wave<br />
CT04/CT22: Yellow, S-wave<br />
CT05/CT23: Black, S-wave<br />
CT06/CT24: Magenta, P-wave<br />
CT07/CT25: Cyan, P-wave<br />
CT08/CT26: Yellow, P-wave<br />
CT09/CT27: Black, P-wave<br />
(43) I/O measurement data 100%/ 0%/ 95%/ 0%/ 85%/ 0%/ 70%/ 0%/<br />
50%/ 0%/ 30%/ 0%/ 15%/ 0%/ 5%/ 0%/<br />
CT10 to CT17: First time<br />
CT28 to CT35: Second time<br />
CT10/CT28: Magenta, S-wave<br />
CT11/CT29: Cyan, S-wave<br />
CT12/CT30: Yellow, S-wave<br />
CT13/CT31: Black, S-wave<br />
CT14/CT32: Magenta, P-wave<br />
CT15/CT33: Cyan, P-wave<br />
CT16/CT34: Yellow, P-wave<br />
CT17/CT35: Black, P-wave<br />
(44) Counter for calibration (CT18/CT36) CT18: First time CT36: Second time<br />
Total/Cancellation/Retry/e10 error/ e11 error/ e12 error<br />
(45) Various correction values for maintenance<br />
mode<br />
All parameters are displayed. 512 bytes at the maximum.<br />
(46) Drum serial number /Cyan/Magenta/Yellow/Black<br />
(47) Machine serial number -<br />
NOTE:<br />
Code conversion<br />
A B C D E F G H I J<br />
0 1 2 3 4 5 6 7 8 9<br />
1-4-6