2BF-5<br />
<strong>Service</strong> items<br />
>>Maintenance<br />
[A]<br />
Counter reset for the maintenance kit A<br />
Description<br />
Description<br />
The "Install MK [A]" message means that maintenance kit A should be replaced at every<br />
300,000 images of printing. The interval counter must be reset using this service item.<br />
MK-810A Maintenance kit A includes the following units:<br />
• TR-810 transfer unit<br />
• FK-810 fuser unit<br />
• Ozone filter<br />
Purpose<br />
To reset the life counter for the transfer unit and fuser unit in maintenance kit A.<br />
Procedure<br />
1.Replace the transfer unit (See page 1-6-12).<br />
2.Replace the fuser unit (See page 1-6-17).<br />
3.Replace the ozone filter (See page 1-6-40).<br />
Start<br />
Enter the service mode (>>Maintenance [A]).<br />
Press the ENTER key twice. The counter for each component is reset immediately.<br />
Completion<br />
Note:<br />
Occurrences of resetting the maintenance kits are recorded on the service status page in<br />
number of pages or images at which the maintenance kit was replaced (See page 1-4-2).<br />
>>Maintenance<br />
[B]<br />
Counter reset for the maintenance kit B<br />
Description<br />
The "Install MK [B]" message means that maintenance kit B should be replaced at every<br />
300,000 images of printing. The interval counter must be reset using this service item.<br />
MK-810B Maintenance kit B includes the following units:<br />
• DV-810K black drum unit<br />
• DK-810 black developer<br />
Purpose<br />
To reset the life counter for the black drum unit and developer in maintenance kit B.<br />
Procedure<br />
1.Replace the black drum unit (See page 1-6-15).<br />
2.Replace the black developer (See page 1-6-15).<br />
Start<br />
Enter the service mode (>>Maintenance [B]).<br />
Press the ENTER key twice. The counter for each component is reset immediately.<br />
Completion<br />
Note:<br />
Occurrences of resetting the maintenance kits are recorded on the service status page in<br />
number of pages or images at which the maintenance kit was replaced (See page 1-4-2).<br />
1-4-10