V in<br />

MaxV<br />

Maximum Current – Max A<br />

Maximum Voltage – Max V<br />

Maximum Power – Max KW<br />

LowV<br />

Low-Mid Max A I in<br />

FIGURE 1.5 INPUT VOLTAGE/CURRENT/POWER RELATION DIAGRAM<br />

The theory of the CP operation comes from the divider circuit built in the load. Because of the nonlinear<br />

characteristic of the divider, the input voltage, input current, and power setting will limit the CP mode of operation.<br />

The CP mode will not allow the load to operate beyond the full range of the Constant Power setting.<br />

AIRFLOW FUNCTION<br />

Airflow plays and important part in power dissipation. The programming electronic load uses cooling fans as a<br />

standard cooling system for removing the heat generated from the power module.<br />

Do not impede or obstruct the ventilation holes for any reason to prevent the power components from overheating.<br />

All <strong>PEL</strong>’s have OTP protection to prevent the unit from overheating. The standard programming electronic loads<br />

have forced air-cooling fans installed as the main cooling system and operate when the power-handling unit is turned<br />

on.<br />

16 M470030-01 Rev A